Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 5.
1. King Pumps: use a ground wire and clamp. See
Fig. 1. Remove the ground screw (Z) and insert
through eye of ring terminal at the end of ground
wire (Y). Fasten ground screw back onto pump
and tighten securely. Connect the other end of the
wire to a true earth ground. Order Part No. 222011
Ground Wire and Clamp.
All Other Pumps: use a ground wire and clamp.
See Fig. 2. Loosen the grounding lug locknut (W)
and washer (X). Insert one end of a 1.5 mm@ (12
ga) minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. Order Part
No. 237569 Ground Wire and Clamp.
Z
Fig. 1
W
Y
Fig. 2
Installation
(ALL PUMPS)
2. Air, fluid, and hydraulic hoses: Use only electrically
3. Air compressor or hydraulic power supply: follow
4. Spray gun: ground through connection to a prop-
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
7. Solvent pails used when flushing: follow your local
Y
TI1052
8. To maintain grounding continuity when flushing or
X
Optional Fluid Outlet Fitting
Z
Part No. 184470 Fluid Outlet Fitting is available for
applications requiring a smaller fluid outlet fitting than
the standard 1–1/2 in. npt(m). The 184470 Fitting is
0864
3/4 npt(m) x M42 x 2.0. Contact your Graco distributor
to order.
conductive hoses with a maximum of 500 feet (150
m) combined hose length to ensure grounding
continuity. Check the electrical resistance of your
hoses at least once a week. If the total resistance
to ground exceeds 29 megohms, replace the hose
immediately.
NOTE: Use a meter that is capable of measuring
resistance at this level.
manufacturer's recommendations.
erly grounded fluid hose and pump.
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.