5.
Install Lock Body in Door:
a. Feed wires through 1-5/16" diameter hole on INSIDE of door while installing lock body (Fig. 6a).
b. Pull wires through hole while inserting lock body. DO NOT push wires back into cylinder hole (Fig. 6b).
Important: Door must remain open during installation. Use door stop.
c. Install, but do not tighten two #12 x 1" combination screws through lock body (Fig. 6a).
Fig. 6a
6.
Install Cylinder:
a. Slide cylinder through collar. Thread cylinder into lock body
(Fig. 7a).
Note: Make sure cylinder is oriented correctly (Fig. 7a1).
b. Tighten cylinder clamp using 7/64" allen wrench (Fig. 7b).
c. Turn the key to make sure that lock functions correctly
(latch, deadbolt, and key).
Fig. 7a
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
Outside Face of Door
Position cylinder so that the logo is right-
Correct
Fig. 7a1
10
Inside Face of Door
(2) #12 x 1"
Do not tighten
side up.
Incorrect
DPS
From Lock Body
Fig. 6b
Fig. 7b