Fault LED (red)
Status
OS (operating status)
11.8

Troubleshooting

The following table lists the possible status and fault messages, the ProLog© status messages that the device can display
by means of the LC display / web interface and the LEDs.
No. Grid
LED Display
LED
1
Waiting for feed-in
2
Generator-Spannung zu
niedrig Batterie-Spannung
zu niedrig
4
Yield counter for daily and
annual yields are displayed
7
Self test in progr.
8
Self test in progr.
10
Temperature in unit too high If the device overheats due to a lack of air cir-
11
17
"Powador-protect discon-
nection" or "External grid
protection shutdown"
18
Resid. current shutdown
19
Generator insulation fault
20
Active ramp limitation
KACO blueplanet 3.0TL3 KACO blueplanet 4.0TL3 KACO blueplanet 5.0TL3 KACO blueplanet 6.5TL3 KACO blue-
planet 7.5 TL3 KACO blueplanet 8.6TL3 KACO blueplanet 9.0TL3 KACO blueplanet 10.0TL3
Explanation
ž The fault relay releases again.
ž The device feeds back into the grid again after a country-
specific time period.
Status description
The start voltage (pre-)set in the device is
higher than the actual voltage. The device
waits for the solar voltage to exceed an ad-
justable value and for a stable grid.
Insufficient generator voltage and power,
status before the transition to night shutdown.
In cases of sufficient sunlight, the unit feeds
into the grid with MPP control so as to maxim-
ise yields.
During the self-test, the following sequence is
run through: 1. S7 (start-up) 2. S75 (load DC
link) 3. S8 (relay and buffer test) Inverter ob-
jective is to switch to S4
Self test of relays, testing of line relays prior to
beginning grid feed
culation, the device switches off. Cause: ambi-
ent temperature too high, device error.
Power limitation: If the generator power is too
high, the device limits itself to the maximum
power (e.g. around noon if the generator ca-
pacity is too large).
The activated grid and system protection has
been tripped.
AFI shutdown as a result of a sudden residual
current in the system
There is an insulation fault on the PV gener-
ator. The feed-in was interrupted.
Internal ramp limiting, e.g.: "Ramp Up" 10 %/
Min • After an overvoltage has been detected,
for example, the device limits its output and
slowly ramps up again (RampUp).
LED
Off
Action
Pers
.
-
B
-
B
-
B
-
B
-
-
Cool off the area
B E
around the inverter.
Uncover the fans.
Contact a qualified
electrician.
-
-
Wait for reactiva-
E
tion. Elektrofach-
kraft benachrichti-
gen, wenn der
Fehler mehrmals
auftritt!
in Fehlerstrom
E
wurde festgestellt.
The feed-in was in-
terrupted.
There is an insula-
E
tion fault on the PV
generator. The
feed-in was inter-
rupted.
-
-
Page 75