Fastening The Mount - Kaco blueplanet 3.0TL3 Series Manual

Hide thumbs Also See for blueplanet 3.0TL3 Series:
Table of Contents

Advertisement

7 Lift the device at the intended positions.
» Continue installing the mount.
6.3

Fastening the mount

CAUTION
Hazard when using unsuitable fixing materials!
If unsuitable fixing materials are used, the device could fall and persons in front of the device may be seri-
ously injured.
Use only fixing materials that are suitable for the mounting base. The fastening materials supplied are
only suitable for masonry and concrete.
Only install the device in an upright position.
C
B
A
D
B
C
Fig. 12: Minimum clearances for wall mounting
Key
1
Mount
2
Fixings for mounting [S6 – Ø 6mm/ 50mm]
3
Screws for mounting 5x 5x50 [Z2+Slot 5x50 Fastening
the mount [See section 6.3} Page 18]]
A
Minimum clearance: 150 mm (without device304.5
mm )
recommended distance475 mm (without device 510
mm *)
B
Minimum clearance: 500 mm
↻ Cardboard packaging with mount and mounting kit removed from the packaging and opened.
1 Mark the mounting position on the wall surface according to the position of the mount by drawing a line.
2 Mark the positions of the drill holes using the slot in the mount.
NOTE: The minimum clearances between two devices, or the device and the ceiling or floor have already been
taken into account in the diagram.
3 Fix the mount to the wall using suitable mounting fixtures from the mounting kit.
NOTE: Make sure that the mount is oriented correctly.
» Proceed with the installation of the device.
Page 18
5
50 mm
1
2
4
3
A
KACO blueplanet 3.0TL3 KACO blueplanet 4.0TL3 KACO blueplanet 5.0TL3 KACO blueplanet 6.5TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6TL3 KACO blueplanet 9.0TL3 KACO blueplanet 10.0TL3
510 mm
1220 mm
160 mm
180 mm
920 mm
Fig. 13: Wall mounting
4
Bracket with detachment protector
5
Screw for securing purposes (1x)
C
Minimum clearance: 700 mm
D
Recommended clearance: 250 mm
582 mm
216 mm

Hide quick links:

Advertisement

Table of Contents
loading