Displaying the firmware version
F Open the Information / SW version menu.
» The device will display the versions and checksums of the software that is currently loaded.
9.7

Access via Modbus

NOTE
In order to make use of the Modbus functionality, we recommend using the "SunSpec-Modbus-Interface"
specification we have made available for the firmware version installed on your device.
Follow the description in the document "Modbus-Protokol.pdf" in order to use the two Excel files with a
high level of process reliability.
↻ Firmware version of device is identical to the specifications of the Sunspec® Modbus®.
1 Enable the entry Network – Modbus TCP - Operation mode / Network services – Modbus TCP
- Operation mode in the menu on the device or on the web interface.
2 If necessary, allow write access.
3 Set up the Port for access. [Default: 502]
» Access via Modbus enabled.