1.4
Identification
You will find the name plate with the following data for service and other require-
ments specific to installation on the right side panel of the product:
Product name
Part no.
Serial number
Date of manufacture
Technical data
Disposal information
Certification marking, CE marking.
1.5
Warnings on the device
A warning sticker is affixed to the device. Read the warnings carefully.
Do not remove the sticker. If the sticker is missing or is illegible, please contact a
KACO representative or distributor.
Article number:
1.6
Target group
All activities described in the document may only be carried out by specially trained personnel with the following qualific-
ations:
Knowledge about how an inverter functions and operates
Knowledge about IP-based network protocols
Knowledge of the Modbus specifications
Knowledge of the SunSpec Modbus specifications
Education concerning the installation and configuration of IT systems
Training in the handling of hazards and risks during the installation and operation of electrical devices and systems.
Education concerning the installation and start-up of electrical devices and systems.
Knowledge of applicable standards and directives.
Knowledge and adherence to this document with all safety notices.
Page 6
KACO blueplanet 3.0TL3 KACO blueplanet 4.0TL3 KACO blueplanet 5.0TL3 KACO blueplanet 6.5TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6TL3 KACO blueplanet 9.0TL3 KACO blueplanet 10.0TL3
KACO blueplanet 10.0 TL3 M2 WM OD IIG0
Part number
1001460
Serial number
00000000012345678
Year Q3 / 19
KACO new energy
Carl-Zeiss-Straße 1
74172 Neckarsulm
Made in Germany
Vmax PV / lsc PV (max) / Inom PV
1000 Vdc /2x 16 A /2x 11 A
Input
V-MPP at Pnom / V- range
470 V - 800 V / 200 V - 950 V
220 V / 380 V (3/N/PE)
230 V / 400 V (3/N/PE)
Nominal voltage
240 V / 415 V (3/N/PE)
Output
Voltage range continuous operation
180 V - 277 V (Ph-N)
Current (maximum continuous)
3 x 15,5 A
Frequency range
45 Hz - 65 Hz
Snom at 230 V Unom
10000 VA
Output
Power
Reactive power
cos phi
0-95 % Snom
1 - 0,3 ind/cap
Environ-
Temperature range
-25°C...+60°C/-13°F...+140°F
ment
Protection class / Ingress protection
I / IP65
none
ARC fault circuit protection
Interface protection according to country
specific requirements, details see manual
No galvanic separation / UTILITY-INTERCONNECTED
Fig. 1: Name plate
Fig. 2: Warning sticker