Installation Of End Cover Assembly To Device - Assa Abloy Yale Delayed Egress Installation Instructions Manual

Exit device
Table of Contents

Advertisement

Delayed Egress
Exit Device
Installation Instructions
3

Installation of End Cover Assembly to Device

1. (J5) Nuisance Delay (Figure 3)
Jumper on - 3 seconds (Default)
Jumper off - immediate alarm
2. (J8) Reset Delay (Figure 3)
Jumper on - 10 seconds (Default)
Jumper off - 20 seconds
3. Slide end cover assembly into exit device.
(Figure 3) Do NOT pinch or crimp wires!
For technical support contact Yale
at 800.438.1951 or support@yalelocks.com
®
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
An ASSA ABLOY Group brand
Exit Device
Connector J2
To Power Transfer Hinge
Optional "O", "S" or
Safe/Secure wire
(Refer to wiring diagram
for wiring)
4. Connect device lock assembly to Connector
J1. (Figure 4)
5. Place wire connectors and excess wire
between end cover and circuit board.
(Figure 4) Check all connections before
proceeding.
2
1
J5 J8
End Cover Assembly
Optional Wires
Lock Assembly Harness
To Power Transfer
5
Place Connector
and Excess Wire
in this Area
4
J1 Connector
Plugs into Device Lock Assembly
5
Connector J2
To Power Transfer Hinge
Connector J1
Plugs into Device Lock Assembly
3
Figure 3
Figure 4
80-9470-0162-000 10/18