Summary of Contents for Assa Abloy Yale nexTouch

  • Page 1 nexTouch ® Touchscreen and Push Button Exit Device Trim Installation and Programming Instructions This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.
  • Page 2: Before You Begin

    Before You Begin template Fire Guard Optional Technology Module Optional Privacy DPS Switch Outswinging Door Left Hand Right Hand Interior Reverse Reverse #3 & #2 Exterior Face a door swinging open toward you. If it swings open to the right, it is a right hand reverse door.
  • Page 3: Prepare Door

    Door Position Switch Option Privacy DPS Switch With Door Position Switch installed and door closed, all keypad functions can be disabled by Privacy Button. Prepare Door DPS Option for Privacy Function template Wood Door: 3/8" Dia. Thru to Hole in Door Face *Metal Door: 3/4"...
  • Page 4: Install Cylinder

    Install Cylinder Tighten counter-clockwise to secure lock. Use key to thread cylinder. Pull key out of cylinder to first blade cut for best operation. If using cylinder other than 1-1/8", a new collar must be used that is sized appropriately for cylinder length. Test Cylinder Test cylinder by turning key counter-clockwise to unlock trim.
  • Page 5 Change Hand of Trim (if necessary) Left Hand Reverse Right Hand Reverse There is a spring inside spindle. Be sure to keep spring for reassembly. Spindle Tighten nut then loosen just enough that spindle tab aligns with top of hole. Be sure spring is inside spindle.
  • Page 6 Install Outside Trim Assembly #10-32 x 1" OHPMS Do not take apart outside assembly. Exit Device Mounting 2 hinge side screws Holes hold outside trim assembly until exit device is installed. All 4 screws MUST be used for proper installation. Do not tighten screws until exit device...
  • Page 7: Install Exit Device

    Install Exit Device #10-32 x 1" PHMS Refer to exit device installation instructions for details of device installation. Tighten all screws. Test Mechanical Lock Function by Key, Lever and Touchpad P/N 80-8470-0900-000 (09-19)
  • Page 8 Install Strike and Optional DPS #10-24 PFHMS DPS Option for Privacy Function Frame *Metal Frame: 3/4" Dia. x 1" See Instructions with DPS Kit * Supplied plastic collar MUST be installed for DPS to function properly. 3-1/2" Strike must be centered with exit device bolt. For proper engagement, door should remain latched and not rattle when pushed, pulled or shaken in/out.
  • Page 9 Install Inside Escutcheon Plate #8 x 1/2" PHWS #8 x 3/8" PRH Wood Sheet Metal #10-32 x 1-1/2" THPMS Inside of Door Optional DPS P/N 80-8470-0900-000 (09-19)
  • Page 10 Attach Cables to Inside Escutcheon Reset Button Keypad Connection External Power Optional Connection Motor Connection P/N 80-8470-0900-000 (09-19)
  • Page 11 Install Inside Escutcheon #8-32 x 5/16" PHMS Avoid pinching cables! Do not tighten screws until escutcheon is flat against plate without excessive pressure. P/N 80-8470-0900-000 (09-19)
  • Page 12 Install Module (optional) Network or Yale Accentra Key Module Optional Network or Yale Accentra Key module must be installed with batteries REMOVED. Install Batteries & Cover Welcome to Yale. P/N 80-8470-0900-000 (09-19)
  • Page 13 Test Electronic Lock Function by Keypad See Programming Instructions to create Master PIN code before testing. Enter PIN code and press to test. Install Exit Device Cover Congratulations, you've installed the Yale nexTouch Lock! ® Continue to customize your product. P/N 80-8470-0900-000 (09-19)
  • Page 14: Programming Instructions

    Programming Instructions 9 Volt Battery Override Terminal Unlock Indicator (Touchscreen Only) Low Battery Lockout Mode Indicator Indicator (Touchscreen Only) (Touchscreen Only) Indicator Light Privacy Button Speaker Exterior Touchscreen Interior Escutcheon (Push Button and Touchscreen) Escutcheon Lock Activation Touchscreen Push Button Master PIN Code must be created before any further programming.
  • Page 15 Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the gear key to continue."...
  • Page 16 Creating User PIN Codes Master PIN code must be created first. *Max User Codes = 500 "Menu Mode, enter number." Enter Master Activate Lock PIN code Press "Register User code. "Register *User code. Press the gear key Press the gear key to continue."...
  • Page 17 Creating User PIN Codes con't Enter 4-8 digit PIN code followed by "Registered. Press the check key to complete. Press the gear key to continue." Adding more User Codes: To end programming: Press Press Enter 4-8 digit PIN code "Completed." Press "Registered.
  • Page 18 Locking & Unlocking Door with Registered Master or User PIN Code Enter PIN Code Press Locking Door with Privacy Button DPS installation is required for this feature. Privacy must be 'Enabled' from feature menu. P/N 80-8470-0900-000 (09-19)
  • Page 19: Resetting Lock To Factory Default

    Resetting Lock to Factory Default Screw Location When lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all Reset programming features are reset to original default Button settings (see Factory Settings). Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock.
  • Page 20 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while unit is in Lockout, the RED locked padlock will appear on the screen. (Main Menu selection #6.) Automatic Re-lock Time: After a successful unlock, unit will re-lock automatically after 3 seconds or for a duration selected in Advanced Lock Settings (Main Menu selection #3 then #1).
  • Page 21: Feature Programming Through Menu Mode Using Master Pin Code

    Feature Programming Through Menu Mode Using Master PIN code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number (Enter digit corresponding to the function to be performed), press the key to continue."...
  • Page 22: Programming Troubleshooting

    Programming Troubleshooting Symptom Suggested Action Touchscreen becomes active when pressed w/whole hand. • Use a larger area of the hand or fingers and verify contact with at least 3 areas. Lock does not respond – door is open and accessible. If touchscreen numbers are visible, check to see if they respond when pressed.
  • Page 23: Hardware Troubleshooting

    Hardware Troubleshooting Door is binding. b. Hinges should not be loose or have excessive wear. For additional hardware troubleshooting, please refer to exit device installation instructions. P/N 80-8470-0900-000 (09-19)
  • Page 24 Product Support Tel 800.438.1951 • www.yalelocks.com Yale Commercial is a business associated with ASSA ABLOY Access and Egress Hardware Group, Inc., an ASSA ABLOY Group company. Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc.