FMT230, FMT250 THERMAL MASS FLOWMETER | CI/FMT230/250-EN REV. B

Temperature data

Temperature resistance for the connecting cable

The temperature at the cable entries of the device is dependent
on the measuring medium temperature T
temperature T
.
amb.
For the electrical connection of the device, use only cables with
sufficient temperature resistance in accordance with the
following table.
T
Temperature resistance for the connecting cable
amb.
≤ 50 °C (≤ 122 °F)
≤ 60 °C (≤ 140 °F)
≤ 70 °C (≤ 158 °F)
From an ambient temperature of T
wires in the connection boxes with the enclosed silicone hoses
need to be additionally insulated.
Note
The signal cable supplied by ABB can be used without
restrictions up to an ambient temperature of ≤ 80 °C (≤ 176 °F).
and the ambient
medium
≥ 70 °C (≥ 158 °F)
≥ 80 °C (≥ 176 °F)
≥ 90 °C (≥ 194 °F)
≥ 60 °C (≥ 140 °F), the
amb.
Environmental and process conditions for model
FMT2xx...
Ambient temperature T
amb.
Measuring medium temperature
T
medium
IP rating / NEMA rating
13
−20 to 70 °C (−4 to 158 °F)
−20 to 150 °C (−4 to 302 °F)
IP 65, IP 67 / NEMA 4X,Type 4X