Device overview
Standard / No explosion protection
Model number
•
Standard
•
Class I Div. 2
•
Class I Div. 1
•
Zone 2, 22
•
Zone 1, 21
Ex marking
Note
•
Depending on the design, a specific marking in accordance with FM applies.
•
ABB reserves the right to modify the Ex-marking. Refer to the name plate for the exact marking.
Designation for model FMT2xx-F2... in Division 2
FM (marking for US)
Certificate
NI: CL I, Div 2, GPS ABCD, T6...T2
NI: CL II,III Div 2, GPS EFG, T6...T3B
DIP: CL II, Div 1, GPS EFG, T6...T3B
DIP: CL III, Div 1,2, T6...T3B
CL I, ZN 2, AEx ec IIC T6...T2 Gc
ZN 21, AEx tb IIIC T85°C...T165°C Db
See handbook for temperature class information
FM (marking for Canada)
Certificate
NI: CL I, Div 2, GPS ABCD, T6...T2
NI: CL II,III Div 2, GPS EFG, T6...T3B
DIP: CL II, Div 1, GPS EFG, T6...T3B
DIP: CL III, Div 1,2, T6...T3B
CL I, ZN 2, Ex ec IIC T6...T2 Gc
Ex tb IIIC T85°C...T165°C Db
ANSI/ISA 12.27.01: Dual Seal
FMT2xx Y0
FM19US0110X
FM19CA0055X
Class I Div. 2 Zone 2, 22
FMT2xx F2
Designation for model FMT2xx-F1... in Division 1
FM (marking for US)
Certificate
XP-IS: CL I, Div 1, GPS BCD,T6...T2
DIP: CL II,III, Div 1, GPS EFG,T6...T3B
CL I, ZN 1, AEx db ia IIB+H2 T6...T2 Ga/Gb
ZN21, AEx ia tb IIIC T85°C...T165°C Db
Permitted supply short-circuit current: 35A
See handbook for temperature class information and installation drawing
3kxf000094G0009
FM (marking for Canada)
Certificate
XP-IS: CL I, Div 1, GPS BCD,T6...T2
DIP: CL II,III, Div 1, GPS EFG,T6...T3B
CL I, ZN 1, AEx db ia IIB+H2 T6...T2 Ga/Gb
Ex ia tb IIIC T85°C...T165°C Db
IN-/OUTPUTS: Urated=30V
Ex ia INTRINSICALLY SAFE
SECURITE INTRINSEQUE
Class I Div. 1 Zone 1, 21
FMT2xx F1
FM19US0110X
FM19CA0055X