Environmental Conditions - Epson TM-T88 Series Technical Reference Manual

Liner-free label paper model
Table of Contents

Advertisement

Environmental Conditions

Operating
Storage
When
packed:
When
packed:
When
unpacked:
Operating
*: When the specified roll paper type is used
92
Thermal paper
5 ° C to 45 ° C {41°F to 113°F}, 10% to 90%
RH, non-condensing (See the operating
environment range below.)
-10 ° C to 50 ° C {14°F to 122°F}, 10% to
90%RH
(paper excluded)
[ RH]
90
65
Operating environment
10
5
34 40 45
Ambient Temperature
Frequency:
5 to 55 Hz
Acceleration: Approximately19.6 m/s² {2G}
Sweep:
10 minutes (half cycle)
Duration:
1 hour
Directions:
XYZ
There is no external or internal visible damage and the unit operates normally after
being subjected to vibration.
Package:
EPSON standard package
Height:
60 cm {23.62"}
Directions:
corner, 3 edges, and 6 surfaces
There is no external or internal visible damage and the unit operates normally after
being dropped.
Height:
5 cm
Directions:
Lift one edge and release it
There is no external or internal visible damage and the unit operates normally after
being dropped while not operating.
Approximately 52 dB (ANSI Bystander position)
NOTE) The values above are measured in the Epson evaluation condition.
Acoustic noise differs depending on the paper used, printing contents, and the setting
values, such as print speed or print density.
("Paper Specifications" on page
Liner-free label paper*
5 ° C to 35 ° C {41°F to 95°F}, 20% to 80% RH,
non-condensing (See the operating
environment range below.)
-10 ° C to 50 ° C {14°F to 122°F}, 10% to
90%RH
(paper excluded)
[ RH]
34°C {93.2°F}, 90
90
80
40°C {104°F}, 6
60
Operating
45°C {113°F},
environment
45
20
10
5
83)
15°C {59°F}, 80
25°C {77°F}, 60
35°C {95°F}, 45
15
25
35
40
45
Ambient Temperature

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm-l90

Table of Contents