Environmental Conditions
Temperatures/
Operating
humidity
Storage
Pressure
Operating
(elevation)
Not operating
(including in
transportation)
Acoustic noise
During
operation
(including using
the autocutter)
0 to 40C, 20 to 80%RH (no condensation)
80
60
40
20
0
Temperatures (C)
When packed (ink not loaded): -20 to 60C, 5 to 85%RH
(no condensation)
-20C or 60C: up to 120 hours
Ink loaded: -20 to 40C
-20C: up to 120 hours
0 to 30C: up to 6 months
40C: up to a month
850 to 1060 hPa (approximately 0 to 1500 m above sea level)
850 to 1060 hPa (approximately 0 to 1500 m above sea level)
Approximately54 dB (ANSI Bystander position)
(Based on Epson evaluation conditions including the use of the
autocutter)
Appendix
30
40
189