1 Overview
Precautions for Safe Use
If the supplied Front Panel is not used, a High Power indicator light must be present in the sys-
tem. This indicator light must be amber in color. It must be either mounted to the robot or inte-
grated into the work cell where it is visible from all approaches or entry points.
Precautions for Correct Use
• Either a Front Panel or equivalent circuits are required to enable High Power to the robot. Re-
fer to XFP Wiring Diagram on page 3-24 for more information.
• If the Front Panel High Power ON / OFF indicator fails, you might incorrectly assume that
High Power is OFF, and the robot is safe. To prevent this, a failed indicator causes an error
(-924) *Front panel HIGH POWER lamp failure* and locks out the High Power enabling until
you replace the indicator. Refer to the XeV+ Language Reference Guide (Cat. No. I605) for
more information about error handling. Refer to High Power Indicator Check Procedure on
page 3-32 for information about High Power indicator operation verification.
Additional Information
• The Front Panel is supplied with an extension cable that must be used to connect it to the
XFP connector on the XSYSTEM cable. Refer to 3-8-1 Installing the Front Panel on page
3-20 for more information.
• Design of the factory-supplied Front Panel E-Stop is in accordance with the requirements of
IEC 60204-1 and ISO 13849.
• If you supply your own Front Panel, its design must comply with the requirements of
IEC 60204-1 and ISO 13849. The E-Stop's push button must comply with ISO
13850 (Clause 5.5.2).
• If an operator is going to be in the work cell with the switch in Manual mode, the
operator must carry an enabling device such as the T20 pendant.
• Whenever possible, perform Manual mode operations with all personnel outside the
workspace.
• Disabling the High Power button violates IEC 60204-1. Do not alter its functionality.
• In Automatic mode, the robot can move unexpectedly. Ensure all personnel remain
clear of the cell when Automatic mode is enabled.
Control Power
LED Indicator
High Power
Enable Button
Use the information in the table below to understand Front Panel item details.
Control Power LED Indicator
1-6
Mode Selection
Switch
Item
Provides an indication that the robot is receiving 24 VDC Control Power
with a green LED.
WARNING
High Power
Indicator
Emergency
Stop Button