Omron i4L Series User Manual page 87

Table of Contents

Advertisement

Pins
3, 16
Line emergency stop inputs
4, 17
5, 18
Muted safety gate channel 1 input
6, 19
Muted safety gate channel 2 input
7, 20
Emergency stop status channel 1 output
8, 21
Emergency stop status channel 2 output
9, 22
Automatic mode status channel 1
10, 23
Automatic mode status channel 2
11, 12,
Reserved for future use.
13, 24,
25
 XUSR Jumper Plug
The XUSR jumper plug is provided for safety equipment troubleshooting only.
Never run a robot system with all jumpers installed. This would leave the system
with no E-Stops.
Additional Information
The XUSR jumper plug is supplied with the robot.
The part number for the XUSR jumper plug is 04736-000.
XFP Connections
Use the information in the following table to understand the signals provided on the XFP connector.
PIN 8
PIN 15
Additional Information
Refer to Front Panel Connections on page 3-21 for more information.
i4L Robots User's Manual (I658)
Description
WARNING
PIN 1
PIN 9
Additional Information
Normally closed contacts on user-supplied safety devices
typically used for other robot or line emergency stop in-
terconnection.
This does not affect emergency stop indication signals on
pins 7, 20.
Causes emergency stop in Automatic mode only.
Internal contacts are closed when Front Panel, Teach
Pendant, and user-supplied safety devices are not ena-
bled / activated.
Internal contacts are closed when the robot is in automat-
ic mode.
3 Installation
3
3-23

Advertisement

Table of Contents
loading