4.3.8 Re-Initialising

To activate any changes made the drive has to be reinitialized. Hence the warning within MotionView
This can be done by cycling the power to the drive.
4.3.9 Non-Module Parameter Settings
In addition to configuring the PROFIBUS-DP option module and depending upon the application there may
be several drive based parameters that will need to be set using MotionView or an Indexer program or via
the PROFIBUS parameter access channel. Such as:
PID34 – Drive Mode (VAR_DRIVEMODE)
PID37 – Reference (VAR_REFERENCE)
PID29 – Enable switch funtion (VAR_ENABLE_SWITCH_TYPE)
Commissioning
Figure 11: REBOOT Message
13
P94PFB01A