LG SV008iS5-2 Manual page 141

Table of Contents

Advertisement

Available languages

Available languages

Protective
Function
1) Wdog error (CPU fault)
H/W Fault
2) EEP error (memory fault)
3) ADC Offset (current feedback circuit fault)
Communication
1) Faulty connection between inverter and keypad
Fault
2) Inverter CPU malfunction
Operating
LOP (Loss of reference from the Option),
Method when the
LOR (Remote)
Speed
LOV (V1),
Reference is
LOI (I),
Lost
LOX (Sub-V2, ENC)
Inverter
1) Load is larger than inverter rating
Overload
2) Selected incorrect inverter capacity
Cause
78
Chapter 5 - Troubleshooting & Maintenance
Exchange inverter
1) Check connector
2) Exchange inverter
Eliminate cause of fault
1) Increase motor and/or inverter capacity
2) Select correct inverter capacity
Remedy