LG SV008iS5-2 Manual page 139

Table of Contents

Advertisement

Available languages

Available languages

Keypad Display
LCD
7-Segment
HW-Diag
COM Error
CPU Error
LOP
LOR
LOV
LOI
LOX
Inv. OLT
NTC open
To reset fault, Press RESET key, Close RST-CM terminals or connect input power.
If a problem persists, please contact the factory or your local distributor.]
Protective
Function
Inverter H/W
HW
Fault
Communication
Err
Error
LP
Operating Method
LR
when the
LV
Frequency
LI
Reference is Lost
LX
IOLT
Inverter Overload
Thermal Sensor
NTC
Opened
Chapter 5 - Troubleshooting & Maintenance
A fault signal is output when an error occurs to the control circuitry of the
inverter. There are the Wdog error, the EEP error, and the ADC Offset for this
fault
This fault is displayed when the inverter cannot communicate with the keypad.
According to the I/O-48 [Operating Method when the Frequency Reference is
Lost] setting, there are three modes: continue operation, decelerate and stop,
and free run,
LOP: Displayed when option frequency reference is lost (DPRAM time out)
LOR: Displayed when option frequency reference is lost (Communication
network fault)
LOV: Displayed when 'V1' analog frequency reference is lost.
LOI: Displayed when 'I' analog frequency reference is lost.
LOX: Displayed when sun-board (V2, ENC) analog frequency reference is lost.
The inverter turns off its output when the output current of the inverter flows
more than the rated level (150% for 1 minute, 200% for 0.5 seconds).
Inverter uses NC thermal sensor for detecting heat sink temperature. If this
message is displayed, the thermal sensor wire may be cut. (Inverter keeps
operating)
76
Description

Advertisement

Chapters

Table of Contents
loading

Table of Contents