Nok Options - Panasonic EYFR03 User Manual

Hide thumbs Also See for EYFR03:
Table of Contents

Advertisement

This setting should be set to match the baud rate used by a serial bar code reader, if one is used.
If this setting is not configured correctly, bar codes will not be correctly processed.
Require VIN to run
Default: No
This setting determines if the qualifier requires a VIN to be entered before tools will be allowed
to run. When set to Yes, the qualifier will be automatically suspended whenever there is no
currently entered VIN. When set to No, the qualifier will not check the VIN before allowing
tools to run.
A VIN may be entered through either the bar code scanner or a network command. The VIN
may be cleared by a network command, a discrete input, or the Clear VIN on batch setting. If
the VIN is cleared while an operation is running and this setting is set to Yes, the qualifier will
immediately suspend until a new VIN is entered.
Clear VIN on batch
Default: No
This setting determines if the qualifier automatically clears the VIN when a batch completes.
When set to No, the qualifier will never automatically clear the VIN. The VIN may still be
cleared by other means, such as a network command or discrete input.
When set to Yes, the qualifier will clear the VIN when an operation completes, regardless of if
the operation is set to repeat. When directly running a parameter, the VIN will be cleared when a
batch is completed. When running a standard group, the VIN will be cleared when all
parameters in the group have completed. When running a free group, the VIN will never be
cleared. When running a job, the VIN will be cleared when the last step in the job is completed.
No VIN match behavior
Default: No
Values: Continue, Stop, Ignore
This setting determines how the qualifier behaves if a VIN if a selection scan that does not match
one of the defined selectors is received. The behavior of this option is described in Chapter 4:
Serial Communications.

NOK Options

Default: Report
Values: Ignore, Display, Report, Count
This setting determines how the unit will handle NOK results (or rejects). The following table
summarizes the behavior for the different levels:
Level
Beep
Ignore
No
Display
Yes
Report
Yes
Count
Yes
EYFR03 User Manual
Chapter 3: Configuring the unit
Show on
Store in
1
Screen
Flash
No
No
Yes
No
Yes
Yes
Yes
Yes
40 of 110
Report to
Overall
2
Network
bad
No
No
No
No
Yes
No
Yes
Yes
Increment
Count
No
No
No
Yes
v1.6.0
20 January 2020

Advertisement

Table of Contents
loading

Table of Contents