Data Format

The below tables show the data available for the input and output slots. The offsets are relative
to the start address for each slot's address space.
Tool IO Module Input
Offset
Size
Name
0
1
Job Number
1
1
Parameter
Number
2
1
Tool Number
3
1
Status
4
1
Count
5
1
Batch
6
2
Timestamp Date
8
4
Timestamp Time
12
2
Last Parameter
Write Date
14
4
Last Parameter
Write Time
18
4
Tightening ID
22
1
Result Status
23
14
Tool Serial
Number
37
25
VIN
Tool IO Module Output
Offset
Size
Name
0
1
Job Number
1
1
Parameter
Number
2
1
Batch
3.0
bit
Suspend
3.1
bit
Batch Reset
3.2
bit
Job Step
Increment
3.3
bit
Job Step
Decrement
3.4
bit
Batch Increment
EYFR03 User Manual
Chapter 10: PROFINET
Type
USINT
Job number. (0 means job not running)
USINT
Parameter number. (0 means parameter not running.)
USINT
Active tool number. (0 means no tool active)
USINT
Status of parameter
0 – None
1 – Cycle
2 – Batch
3 – Reject
4 – Batch NOK (batch complete with a counted reject)
USINT
Number of tightenings performed in the current batch for the
parameter.
USINT
Number of tightenings required for a batch in the parameter.
DATE
Date portion of timestamp of the last tightening
TOD
Time portion of timestamp of the last tightening
DATE
Date portion of the last time the parameter of the last
tightening was written
TOD
Time portion of the last time the parameter of the last
tightening was written
UDINT
ID number of the last tightening
0 – OK; 1 – NOK
USINT
CHAR[14]
Serial number of the tool that performed the last tightening
CHAR[25]
VIN of the last tightening.
Type
USINT
Job number to run.
USINT
Parameter number to run. Ignored if Job Number is not 0.
255 means temporary parameter with information below.
USINT
Sets the batch size for the selected parameter. Ignored if Job
Number is not 0. If this value is 0, the parameter size stored
in the EYFR03 will be used.
BOOL
When set, suspends on the interface without stopping a
running parameter or job.
BOOL
When this value changes from false to true, the batch count of
the currently running parameter on the interface is reset.
BOOL
When this value changes from false to true, the EYFR03 will
move to the next step in the active job.
Ignored if Job Number is 0.
BOOL
When this value changes from false to true, the EYFR03 will
move to the previous step in the active job.
Ignored if Job Number is 0 or if already on the first step in the
job.
BOOL
When this value changes from false to true, the EYFR03 will
increment the count as if a valid tightening was performed.
102 of 110