Certification Codes And Standards; Heater Components - Jandy JXi 200 Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

Jandy
, JXi
Gas-Fired Pool & Spa Heater
®
2.7

Certification Codes and Standards

DESIGN CERTIFIED
COMPLIANT
NATIONAL CODES
All Jandy heaters must be installed in accordance with the local building and installation codes as per the utility or Authority Having Jurisdiction
(AHJ). In the absence of local codes, please refer to the latest edition of the national codes for installation.
JXi pool and spa heaters meet or exceed the requirements of energy conservation regulations such as those in states that have disallowed the
use of continuously lit pilot type ignition sources.
2.8

Heater Components

a
b
a
Flue Temperature Sensor
combustion will stop and a fault will be displayed.
When current is passed through the ceramic
b
Hot Surface Igniter
material of the igniter it will achieve temperatures
great enough to initiate combustion of the air/fuel mixture.
Provides energy for ignition, monitors flame quality
c
Ignition Control
and controls the gas valve. Upon call for heat, the
blower is activated to purge the combustion chamber. Electrical power is
then applied to the hot surface igniter. When ignition temperature is
attained, the gas valve opens and ignition occurs. If stable flame is detected
the igniter will power down. If stable flame is not detected the control
system will close the valve to prevent further gas release. If a total of 3
ignition attempts fail an ignition fault is displayed.
Prevent water of excessive temperatures from
d
High Limit Switches
being discharged from the heater. If either switch,
one at the heat exchanger first pass 135°F (57°C) and one at the heat
exchanger outlet 150°F (65°C), senses excessive temperature, the gas
valve will close and combustion will stop.
|
Installation & Operation Manual
USA
ANSI® Z21.56
California South Coast Air Quality Management
District's (SCAQMD) Rule 1146.2
National Fuel Gas Code
NFPA® 54/ANSI Z223.1
Pay particular attention to the chapter addressing
Venting of Equipment
t
o n
F r
c
d
Monitors temperature at the exhaust flue. If
excessive temperatures are detected,
Indicates a safety control equipped to protect internal
components and extend the life of the heater.
CSA (Canadian Standards Association)
Minimum combustion air requirements MUST be followed
for proper and safe operation. Failures may occur when
only the minimum combustion air openings are used.
Header
R
e a
r
e
d
e
Pool/Spa Water Temperature Control
will operate to attain and maintain the water temperature according to the
heater settings. Two separate thermostat settings are supported, typically
used to set pool and spa temperatures.
f
Water Pressure Switch
header inlet. If insufficient pressure is detected, the display will indicate a
"Check Flow" fault and combustion will stop.
g
Controls gas flow into the burner. Enables flow when the
Gas Valve
temperature control calls for heat and all safety controls
enable operation. It also regulates gas pressure to -0.2" WC (Water Column)
below the air pressure at the blower inlet. Necessary pressure regulation
cannot be accomplished with common (positive pressure) gas valves.
h
Combustion Blower and Air Ori ce
is passed through the burner for combustion. The fan will operate for
several seconds before flame initiation and after the flame is extinguished
to purge the combustion chamber for a clean burn and to expel any
residual exhaust gas.
i
Air Pressure Switch
flowing through the combustion system by sensing pressure. If air flow is
inadequate, combustion will stop and a fault will be displayed.
ENGLISH
CANADA
CSA 4.7
Natural Gas and
Propane Installation Code
CAN/CSA-B149.1
g
f
h
Senses water temperature by
means of a thermistor. Heater
Senses whether or not water is available to
the heater by measuring back pressure at the
Draws in air and fuel gas
creating an air/fuel mixture that
Monitors the vacuum (negative pressure) within
the blower housing. This switch verifies that air is
Page 5
i

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jxi 260Jxi 400Jxi200 seriesJxi260 seriesJxi400 seriesJxi200n ... Show all

Table of Contents