FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed
where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions
in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices
and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which may cause serious injury, property damage, or death.
ATTENTION INSTALLER – This manual contains important information about the installation, operation and safe use of this product. This information should be given
Do you have a question about the JXi 200 and is the answer not in the manual?
Questions and answers
Roger Cross
February 11, 2025
After a successful ignition of JXI260P and approximately 10 minutes of run time there is an uncontrolled ignition event. The the combusted gas exits the exhaust manifold. The audible report is at the level of a 12 gauge shot gun. The gas pressure was verified at the control valve inlet.
ID plate JXI260P Serial number LT EC02 0501 0520 0981
Page 1
Installation and Operation Manual Gas-Fired Pool and Spa Heater ™ Models: WARNING FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
READ AND FOLLOW ALL INSTRUCTIONS Introduction This manual provides installation and operation instructions for the Jandy JXi pool and spa gas heater product line. Read these installation and operation instructions completely before proceeding with the installation. Consult Zodiac Pool Systems LLC (“Zodiac”) with any questions regarding this equipment. To obtain additional copies of this manual contact us at 800-822-7933.
If change is required to any of the above; See section 5.3 for adjustment instructions. contact your local Jandy distributor, visit www.jandy.com or call technical support at Review Special Precautions for liquid propane heaters (Section 4.3) 800.822.7933.
All Jandy heaters must be installed in accordance with the local building and installation codes as per the utility or Authority Having Jurisdiction (AHJ). In the absence of local codes, please refer to the latest edition of the national codes for installation.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Heater Components Header Monitors temperature at the exhaust flue. If Senses water temperature by Flue Temperature Sensor Pool/Spa Water Temperature Control excessive temperatures are detected, means of a thermistor. Heater combustion will stop and a fault will be displayed.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 2. Getting Started The requirements for pool heaters include the following: Install the JXi in accordance with the procedures • Field assembly (if required) in this manual, local codes and ordinances, and in •...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Required Equipment Please ensure that the following equipment is available to the installer at the time of installation. 2.2.1 Tools Flathead Safety Eyewear Gloves Phillips Screwdriver Pipe Wrench...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 3. Location Requirements Equipment can weigh up to 156 lbs. (57 kg). Use suitably rated mounting surface materials to avoid The JXi heater is shipped from the factory with an risk of settlement, and never use sand to level the exhaust vent confi gured for outdoor installation.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Outdoor Installations • Away from rainwater runoff • Away from potential sprinkler water intrusion Locate the heater: • So that the top of the heater is at least 3 feet (1 m) below any overhang •...
Page 12
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 3.2.1 Anchor Bracket Installation NOTE: Concrete screws are not provided in the anchor bracket kit. Use size 1/4 in x 2-1/4 in galvanized Anchor brackets do not come standard with the or plated concrete screws and washers.
Any equipment which All outdoor 50 in shelter and exhausts air from the room where the heater 323 cm JXi 200 indoor installations 65 in is installed can deplete the combustion air must have JXi 260...
Page 14
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ WARNING Do not store any chemicals, cleaners, or other corrosive material near combustion air openings or in the room. Avoid locating appliance vents in the vicinity of combustion air openings. Failure to prevent corrosive materials from mixing with combustion air can result in reduced heater life and unsafe heater operation.
Page 15
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ • Locate the vent terminal so that it will not be Connect the vent pipe to the heater vent collar damaged by pedestrians and other traffi c, and so with an air-tight corrosion-resistant clamp.
Page 16
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 3.3.5 Exhaust Venting • Vent opening should be well away from landscaping or other obstructions that would When the JXi heater is installed indoors or in an prevent free air flow to and from vent terminal.
Page 17
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ It is recommended that all venting be engineered by a licensed mechanical contractor National Fuel Gas code ANSI Z223.1 (NFPA ® ® Codes* CAN/CSA-B149.1 Pipe Sizing Special Gas Vent Length †...
Page 18
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 3.3.6 Indoor and Outdoor Shelter Exhaust Double check that there are no possible leak Conversion paths between joints. If a leak path is identifi ed or suspected it can be sealed using red RTV 600° F For both Category I and Category III vent types the rated silicone adhesive.
Page 19
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 3.3.7 Indoor and Outdoor Shelter Exhaust Category III: Appliance can be vented vertically Termination to terminate at the roof or vented horizontally to terminate at a side wall. Side wall vents must be...
Page 20
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Vent the heater vertically using Al29-4C stainless steel components. Consult manufacturers such Exhaust Outlet as Z-Flex or Heat Fab to obtain approved ® ® Exhaust Grill components. Venting materials must comply with Backplate 1738 for Category III, Special Gas Vent.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 4. Gas Connections WARNING Gas piping installation must be in accordance with The JXi pool and spa heaters are designed for use with either natural the latest edition of ANSI Z223.1 and all local codes.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ ATTENTION Do not use fl exible appliance connectors on any gas connections unless the connector is CSA approved for outdoor installation, and is marked with the BTUH capacity (which must be equal to or greater than the heater rated input) and the type of gas (Natural or LP). Also, any fl exible connectors, such as CSST buried underground must be certifi ed for underground installation and meet all applicable codes.
Min gpm (lpm) Max gpm (lpm) and thermal regulator valve (TRV) to accommodate fl ow rates delivered to the heater from a minimum of JXi 200 30 (114) 100 (379) 30 gallons per minute (gpm) to a maximum fl ow of...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 20.0 JXi 200K BTU Heater JXi 260K BTU Heater 18.0 JXi 400K BTU Heater JXi VersaFlo™ Bypass 16.0 14.0 12.0 10.0 Flow Rate (GPM) Figure 10. Head Loss Chart For ASME heater models JXi400NC, JXi400PC, JXi260NC and JXi260PC please go to “Appendix A.
Page 25
Section 5.1.1. Figure 12. • Use approved NSF adhesive to glue the tailpiece The top inlet is intended for use with the Jandy Versa onto the cut pipe, or sweep elbow. Plumb sweep elbow. Plumbing in this confi guration ®...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ • Repeat the above steps for the manifold outlet. Union Nut Sweep Elbow Again paying special care to ensure proper Cut Pipe seating of the union tailpiece o-ring.
A pressure relief valve is not supplied with the JXi heater. However, Jandy does offer a PRV Kit # R0336101. The following instructions are for use with this kit only. All other equipment installations need to be in accordance with the manufacturers instructions.
Page 28
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 5.5.1 Install Pressure Relief Valve Kit R0336101 For ASME heater models JXi400NC, JXi400PC, JXi260NC and JXi260PC please go to “Appendix A. ASME Header” on page 55. ®...
Page 29
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Header Type “A” Header Type “B” For header type B: Assemble the 3/4 in threaded Install a discharge pipe from the pressure relief nipple, elbow and pressure relief valve. Make sure to valve discharge opening to a safe area.
All questions should be directed to technical support • Always follow pool chemical manufacturer’s at 800.822.7933. Additional information can be instructions when adding chemicals to pool. found at www.jandy.com. Be sure to adhere to the following: Section 6. Electrical Connections Alternate 120V Wiring*...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Wiring connections must be made exactly as shown The heater comes factory-wired for installation with in the wiring diagram found on the inside of the 240 Volt, 60 Hz AC fi eld electrical supply. If the heater door.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Maintenance Disconnect Means - The National Secure the conduit to the heater body panel at Electrical Code (NEC ) requires one or more ® ® the knockout using a suitable conduit connector or means to simultaneously disconnect all ungrounded elbow.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Figure 16. Input Conversion Process Bonding National Electrical Code (NEC ) requires bonding ® ® of the Pool Water. Where none of the bonded In the United States the National Electrical Code ®...
If you are setting up a new pool or spa system, or if you have any questions about your heater control system, please call Jandy technical support at 800.822.7933. Connecting to Remote Pool-Off-Spa • Connect the three wires to the Spa, Pool &...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 7.2.1 Install the Remote TSTAT NOTE: If you install a time clock to control the filter pump operation, it is recommended that the time clock • Turn off the power to both the pool/spa control have its own low voltage (Fireman’s) switch to...
Page 36
Multiplex the four wires from the indoor controller. PCB Kit, which includes the Multiplex Board (part # 6584) must be used. Call Jandy Technical Support at • Check all wiring, then apply power to both the 800.822.7933 with any questions.
7.3.3 To Stop the Heater and Prevent Firing • After pressing menu, the display will show After Connecting to An External Controller JANDY REMOTE OFFLINE PUSH MENU TO ENABLE. • Turn power to the heater ON. The heater display shows: JANDY REMOTE ONLINE PUSH MENU TO DISABLE.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ First-Time Start-Up Procedure • Confi rm that pool water is fl owing normally through the pool system and equipment. WARNING • If it is a new pool or spa installation, operate the...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ To Turn Off Gas to the Heater • Remove the rear panel or top. • Set temperature thermostat controls to their • Toggle gas control switch to OFF.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Operating the Controller Unless the heater is connected to a remote GAS HEATER IS OFF controller, all operations are set up and programmed PRESS POOL OR SPA through the control panel on the top of the heater.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ To Maintain Pool or Spa Heat: Performing Seasonal Shutdown (Requires additional external relay and wiring and Complete shutdown instructions are as follows. must be setup in installer configuration) Refer to Figure 21.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 9. Maintenance The TRV ensures the heater operates at it’s optimal efficiency and if properly maintained will extend the If the heater is not going to be used for an extended life of the heater.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 9.1.1 Saturation Index The practice of putting tablet-based sanitizer in the skimmer basket can produce heavily chlorinated PH, Total Alkalinity (TA), temperature, Calcium water with very low pH. If this comes in contact...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ • Where possible, shelter the pool from prevailing • The greatest source of heat loss in a swimming winds with well-trimmed hedges or other pool is through evaporation. It can account for landscaping, cabanas, or fencing.
Page 45
• Inspect the combustion blower for damage. a year or as needed. Routine inspections are a critical to the safety and long life of your Jandy pool • Conduct a normal operating cycle and observe that the sequence proceeds as intended.
Zodiac Pool Systems LLC strongly recommends that you call a qualified service technician to perform all service and repairs on the heater. To locate a licensed or qualified technician service company, call Jandy Technical Support at 800.822.7933, or visit www.jandy.com.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 10.2 Service Diagnostic Messages The controller monitors several functions of the heater. In the event of a malfunction, the controller will display a FAULT message. The following table lists the Heater Service Messages along with potential causes and remedies.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 10.3 Ignition Control LED Service Codes In addition to service diagnostic messages, the ignition controller has an LED light that flashes to indicate various ignition control faults. The table below lists the LED codes and the corresponding fault description. To diagnose possible cause and remedy, refer to Section 10.2, Service Diagnostic Messages.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 12. Spare Parts Using genuine Zodiac factory replacement parts helps to ensure the ongoing quality and reliability of our products. Unauthentic parts might seem okay on the surface, but they often fall short of factory standards, and they typically lack the backing you get from an established, global manufacturer like Zodiac.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 12.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram For ASME heater models JXi400NC, JXi400PC, JXi260NC and JXi260PC please go to “Appendix A. ASME Header” on page 55.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 12.3 Heat System Spare Parts List and Exploded Parts Diagram The following JXi Models are equipped with a Cupronickel (CuNi) heat exchanger. • JXI260NN • JXI400NN •...
Page 52
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 12.3.2 Burner Assembly model 200 model 260 model 400 Key No Description **LP Blower Assembly Kit R0591100 R0591100 R0591100 R0591100 R0591100 R0591100 Air Intake Grate Kit R0591200...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 12.4 Water System Spare Parts List and Exploded Parts Diagram For ASME heater models JXi400NC, JXi400PC, JXi260NC and JXi260PC please go to “Appendix A. ASME Header” on page 55.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 12.5 Electrical System Spare Parts List and Exploded Parts Diagram Key No* Description model 200 model 260 model 400 Ignition Control Kit R0456900 R0456900 R0456900 Transformer Kit...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 13. Appendix A. ASME JXi260PC and JXi260PS. The corresponding sections from the manual are cross referenced with Header page numbers at the beginning of each section.
Page 57
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.3.1 Water Inlet Piping (from “Section 5.2.2 NOTE: When connecting CPVC pipe to the metal recepticle Zodiac Pool Systems LLC recommends Water Inlet Piping” on Page 50)
Page 58
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.3.2 Install Pressure Relief Valve kit #R0336102 Assemble the 3/4” threaded nipple and elbow. Make sure to get a sung fi t. Do not overtighten. Please double check that you have all necessary parts to complete the installation.
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.4 Cabinet Assembly Spare Parts List and Exploded Parts Diagram (From Section “12.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram” on page 50) Key No...
Page 60
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.4.1 Combustion Chamber Assembly (From Section “12.3.1 Combustion Chamber Assembly” on page 51) Key No Description model 260 model 400 Exhaust Elbow Assembly Kit R0590200 R0590200 Band Clamp Kit...
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.5 Water System Spare Parts List and Exploded Parts Diagram (From Section “12.4 Water System Spare Parts List and Exploded Parts Diagrams” on page 53) Key No...
Page 62
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ NOTES Page 62...
Page 63
Jandy Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ NOTES Page 63...
Need help?
Do you have a question about the JXi 200 and is the answer not in the manual?
Questions and answers
After a successful ignition of JXI260P and approximately 10 minutes of run time there is an uncontrolled ignition event. The the combusted gas exits the exhaust manifold. The audible report is at the level of a 12 gauge shot gun. The gas pressure was verified at the control valve inlet. ID plate JXI260P Serial number LT EC02 0501 0520 0981