Jandy LRZ Electronic Installation And Operation Manual

Jandy LRZ Electronic Installation And Operation Manual

Legacy pool and spa heater by zodiac
Hide thumbs Also See for LRZ Electronic:
Table of Contents

Advertisement

Jandy
®
Pool and Spa
Heater by Zodiac
ModeL Zodiac LRZ eLectRonic
natuRaL GaS and LP
note: LP Gas for outdoor use only
WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified
in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements
exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with
sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and instructions that
accompany this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can
cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac
Pool Systems, Inc. strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this
appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Legacy
If these instructions are not followed exactly, a fire or explosion may result,
causing property damage, personal injury, or death.
inStaLLation and
oPeRation ManuaL
enGLiSH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LRZ Electronic and is the answer not in the manual?

Questions and answers

Summary of Contents for Jandy LRZ Electronic

  • Page 1 Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces.
  • Page 3: Table Of Contents

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 3 Installation and Operation Manual table of contents Section 1. General information ....... 5 Section 6. electrical........22 1.1 Introduction ............5 6.1 General Information .........22 1.2 Consumer Information and Safety .....5 6.2 Main Power ............22 1.2.1...
  • Page 4 Page 4 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual table of contents (continued) Section 9. troubleshooting ......35 9.1 General Heater Troubleshooting ......35 9.2 Service Codes ..........35 Section 10. Professional Maintenance and Service ..38 10.1 General Information .........38...
  • Page 5: Section 1. General Information

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 5 Installation and Operation Manual Section 1. General information WaRninG The U.S. Consumer Product Safety Commission introduction warns that elevated water temperature can be hazardous. Consult heater operation and installa- This manual provides installation and operation tion instructions for water temperature guidelines instructions for the Legacy Model LRZ electronic before setting temperature.
  • Page 6: Swimming Pool Energy Saving Tips

    Page 6 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual • Failure to perceive heat Warranty The Legacy Model LRZ electronic heater is sold • Failure to recognize need to leave spa with a limited factory warranty. Details are specified on the back cover of this manual.
  • Page 7: Technical Assistance

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 7 Installation and Operation Manual technical assistance A factory approved vent cap for all outdoor installations where wind conditions may cause Consult Zodiac Pool Systems, Inc. or your local downdrafting.
  • Page 8: Dimensions

    Page 8 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual When requested, the heaters can be configured table 1. altitude designations For the Legacy Model LRZ Heater and shipped for higher altitudes. For field...
  • Page 9: Section 2. Installation Instructions

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 9 Installation and Operation Manual shelter is an enclosure not normally occupied which Section 2. installation instructions does not communicate directly with occupied areas. Check the rating plate on the heater or the Parts...
  • Page 10: Flooring

    Page 10 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual table 2. Minimum Heater clearances From combustible Surfaces table 2. dégagements Minimaux à assurer entre les Parois de L'appareil et les constructions combustibles...
  • Page 11: Indoor And Outdoor Shelter

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 11 Installation and Operation Manual In the United States the vent system shall Ne pas installer ce chauffe-piscine sous une terminate at least four (4) ft (1.2 m) below, four (4) saillie mesurant moins de 3 pi de hauteur.
  • Page 12: Section 3. Venting

    Page 12 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual All indoor installations must have openings to Une remise extérieure (au Canada seulement) outside air for combustion, ventilation, and dilution est un endroit inoccupé qui ne communique pas of flue gases from inside the building, see Figure directement avec les endroits occupés.
  • Page 13: Vent Pipe Sizing And General Installation

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 13 Installation and Operation Manual notes: 1. Use approved roof jack. Figure 5. indoor installation Venting (uSa), or outdoor Shelter (canada) 3.2.2 indoor and outdoor Shelter WaRninG installations Do not store any chemicals, cleaners, or other...
  • Page 14: Inspection And Replacement Of Existing Vent System With New Components

    Page 14 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual In Canada, CAN/CSA B149.1. However, if an existing venting system must be used, be sure to carefully inspect the venting Avoid long horizontal runs of the vent pipe, and system to ensure that it is in good condition and 90°...
  • Page 15 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 15 Installation and Operation Manual table 5. Gas Supply Pressure Requirements caution Supply Pressure Minimum Maximum Permanent damage to the gas valve will occur if the following procedures are not followed. Natural Gas 5.5 inches W.C. 10.0 inches W.C. (1.4 kPa) (2.5 kPa) attention LP Gas 10.0 inches W.C. 14.0 inches W.C. Vous endommagerez la soupape de gaz si vous ne (2.5 kPa) (3.5 kPa)
  • Page 16: Manifold Pressure

    Page 16 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Manifold Pressure For ALL installations the combustion air openings requirements of Table 3 and NFPA54 Confirm that gas supply pressure is correct. If / ANSI Z223.1 MUST be followed for safe and...
  • Page 17: Automatic Flow Control Valve

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 17 Installation and Operation Manual AQUAPURE MANUAL BY-PASS DETAIL MANUAL BY-PASS IS USED WHEN FILTRATION RATE EXCEEDS 125 GPM Figure 7. typical Piping installation instructions have been written to include the steps...
  • Page 18 Page 18 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Proceed as follows: 11. For an existing installation, remove the tube gaskets and clean the header's mating surface of For an existing installation, drain the heater by removing the two drain plugs on the inlet/outlet any corrosion or debris.
  • Page 19: Connections At Heater

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 19 Installation and Operation Manual 22. Use plastic wire ties to refasten the temperature sensor, high limit switch and water pressure switch wires to each other. Bundle the wires near the control panel and fasten them with a wire tie.
  • Page 20: Pressure Relief Valve And Temperature Relief Valve

    Page 20 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Pressure Relief Valve and A pressure relief valve is not supplied with the Legacy Model LRZ electronic heater. However, it is temperature Relief Valve...
  • Page 21: Auxiliary Components, Chlorinators, Ozone Generators, And Sanitizing Chemicals

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 21 Installation and Operation Manual 11. Install the adapter on the PRV and tighten using • When chemical feeders are used, plumb the two wrenches. Use the mark made earlier on the...
  • Page 22: Section 6. Electrical

    Page 22 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Section 6. electrical WaRninG CONNECT WIRES INSIDE HEATER eLectRicaL SHocK HaZaRd. This heater contains wiring that carries high voltage. Contact with these wires may result in severe injury or death. aVeRtiSSeMent POSSIBILITÉ DE CHOCS ÉLECTRIQUES. Ce système de chauffage contient du filage de haut voltage. Un contact avec ces fils peut résulter en WIRES AS SHIPPED des blessures sérieuses ou la mort. CONDUIT caution ELBOW Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and...
  • Page 23 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 23 Installation and Operation Manual FUSE TRANSFORMER FV+ FV- IGNITION CONTROL B B B B B B B B B B B B B B B B B B B B B B B K...
  • Page 24: Bonding

    Page 24 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Bonding 6.4.1 connection to a Remote Pool-off-Spa Selector (3-Wire caution connection) To prevent premature failure of the appliance resulting from stray voltages and voltage differen- 6.4.1.1 install the Remote Pool-off-Spa tials, the heater must be bonded to other equipment Selector which is part of the pool plumbing system with a solid copper wire not smaller in diameter than 8 AWG, 6 AWG in Canada.
  • Page 25: Configure The Control Panel

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 25 Installation and Operation Manual Restore power to the heater and the pool/spa 6.4.2.2 configure the control Panel control system. Make sure the control is in the OFF mode.
  • Page 26: Section 7. Operating Instructions

    Page 26 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Section 7. operating instructions caution Do not use this heater if any part has been under normal operation water. Immediately call a qualified service techni- cian to inspect the heater and replace any part of The Legacy Model LRZ electronic heater is the control system and any gas control which has capable of automatic operation based on a call for been under water.
  • Page 27: Operating The Controller

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 27 Installation and Operation Manual and shutdown instructions and temperature control 7.3.2 Pool Mode - (normal Heat) operation. To enable the pool mode, press PooL . The The heater may not start on the first try. Air in...
  • Page 28: User Setup Options

    Page 28 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual user Setup options To select the length of time for the spa to run, use the up or down button to scroll to display The User Setup options allow the user to select SeLect SPa tiMeR tiMe SeLection .
  • Page 29: Lighting And Shutdown Procedures

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 29 Installation and Operation Manual Lighting and Shutdown Procedures the thermostat setting (desired temperature) to be greater than the water temperature. The igniter lights the burner when the thermostat calls for WaRninG heat.
  • Page 30: Operating Instructions

    Page 30 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual FoR YouR SaFetY Read PRÉcautionS À LiRe BeFoRe oPeRatinG aVant d’utiLiSeR aVeRtiSSeMent: WaRninG: Si vous ne suivez pas ces instructions if you do not follow these instructions exactly, a à...
  • Page 31: Temperature Rise

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 31 Installation and Operation Manual temperature Rise Make sure the pool filter is clean before making any pressure switch adjustment. A dirty filter will note A temperature rise measurement kit is needed restrict the water flow and the pressure switch cannot to perform this test. order part number...
  • Page 32: Section 8. Maintenance

    Page 32 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Set the heater's control panel to the "OFF" heater internal bypass assembly also affects measured temperature rise. position. Start the filter pump. Section 8. Maintenance After three minutes, note and record the ther- mometer reading.
  • Page 33: Seasonal Care

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 33 Installation and Operation Manual Seasonal care After all water has drained from the heater, check for mineral buildup in the openings. caution Use compressed air to blow out any standing Do not operate this heater outdoors at temperatures water remaining in the heat exchanger.
  • Page 34: Owner Inspection

    Page 34 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Be sure all combustion air and ventilation WaRninG openings are not blocked. Check for spider webs Improper installation or maintenance can cause and other debris inside the heater, in the vents on...
  • Page 35: Section 9. Troubleshooting

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 35 Installation and Operation Manual Section 9. troubleshooting caution For your safety, when starting the heater, keep your General Heater troubleshooting head and face away from the burner area opening to prevent any risk of personal injury. Table 8 lists some of the more common problems, causes and solutions encountered when attention running the heater.
  • Page 36: Troubleshooting Guide

    Page 36 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual table 8. Legacy Model LRZ electronic troubleshooting Guide Symptom cause Remedy Pump not operating A. No power A. Check circuit breakers and power source. Pump defective B. Replace.* Incorrectly wired C. Recheck wiring.* Pump relay defective D. Replace pump relay.*...
  • Page 37 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 37 Installation and Operation Manual table 9. Legacy Model LRZ electronic Heater Service diagnostic Guide display Fault cause Remedy Display shows 1. Pump is not running. 1. This is a normal display when the pump is oFF. no no FLoW Service Required.
  • Page 38: Section 10. Professional Maintenance And Service

    Page 38 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Section 10. Professional filter and strainers are not clogged, that there are no mispositioned water valves, that the gas or electric Maintenance and Service power supplies are not shut off and that time clocks are properly adjusted.
  • Page 39: Electrical Troubleshooting

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 39 Installation and Operation Manual shuts off the gas valve and shuts the heater down. Temperature Control - The Legacy Models are equipped with an electronic control which senses...
  • Page 40: 10.4.2 Controller

    Page 40 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual violet wire from the pressure switch enters the two-pin utility company problem. Arrange for correction of the connector on the controller. If there is not 20-28 Volts voltage as appropriate.
  • Page 41: Temperature Limit Switches Circuit

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 41 Installation and Operation Manual No voltage here means that the wire assembly is 10.4.3.5 temperature Limit Switches bad and needs to be replaced. 20-28 Volts AC nominal...
  • Page 42: Section 11. Replacement Parts

    Page 42 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual Section 11. Replacement Parts by the ignition control, test point 12 and test point 10, with the igniter energized. This voltage will be applied only during igniter heat up or trial for ignition.
  • Page 43 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 43 Installation and Operation Manual TRANSFORMER FV+ FV- FUSE IGNITION CONTROL B B B B B B B B B B B B B B B B B B B B B B B K...
  • Page 44: Parts List

    Page 44 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual 11.2 Parts List Key Model Order Key Model Order Description Part No. Description Part No. Water System-Polymer (continued) Main Gas assembly Burner Tray Assy, Natural 125-400 R0468901-05 3" Coupling Nut Kit w/ O-ring...
  • Page 45: General Exploded View

    Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 45 Installation and Operation Manual 11.3 General exploded View...
  • Page 46: Detailed Exploded View

    Page 46 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Installation and Operation Manual 11.4 detailed exploded View 65, 66 15,16...
  • Page 47 Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ® ENGLISH Page 47 Installation and Operation Manual 65,66 15,16...
  • Page 48 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 | www.ZodiacPoolSystems.com ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license. All trademarks referenced herein are the property of their respective owners. ©2012 Zodiac Pool Systems, Inc. H0299500 Rev J 1202...

This manual is also suitable for:

Zodiac lrz electronic

Table of Contents

Save PDF