Jandy JXi 200 Installation And Operation Manual

Jandy JXi 200 Installation And Operation Manual

Jandy pro series gas-fired pool and spa heater
Table of Contents

Advertisement

JXi™ Gas-Fired Pool and Spa Heater
WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in
which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or
maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow
warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation can create carbon
monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety,
Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent
occupied spaces. Improper installation and/or operation will void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY,
A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY
DAMAGE, PERSONAL INJURY, OR DEATH.
INSTALLATION AND

OPERATION MANUAL

Jandy Pro Series
Models 200, 260, 400

Advertisement

Table of Contents
loading

Summary of Contents for Jandy JXi 200

  • Page 1: Operation Manual

    INSTALLATION AND OPERATION MANUAL Jandy Pro Series JXi™ Gas-Fired Pool and Spa Heater Models 200, 260, 400 IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY WARNING DAMAGE, PERSONAL INJURY, OR DEATH. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists.
  • Page 2: Table Of Contents

    Page 2 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Table of Contents Section 1. General Information ....... 3 Section 7. Optional Remote Controls ... 26 Technical Assistance .......... 3 Connecting to a Remote Pool-Off-Spa Selector (3-Wire Connection) .........
  • Page 3: Section 1. General Information

    ENGLISH Section 1. General Information Read the installation and operation instructions This manual provides installation and operation completely before proceeding with the instructions for the Jandy Pro Series JXi pool and spa installation. gas heater product line. Technical Assistance Web: www.jandy.com...
  • Page 4: Specifications

    If change is required to any of †For gas pipe size requirements see Section 4 the above; contact your local Jandy distributor, visit www.jandy.com or call ‡ All readings must be taken while the heater is operating technical support at 800.822.7933.
  • Page 5: Certification Codes And Standards

    All Jandy Pro Series heaters must be installed in accordance with the local building and installation codes as per the utility or Authority Having Jurisdiction (AHJ). In the absence of local codes, please refer to the latest edition of the national codes for installation.
  • Page 6: Section 2. Getting Started

    Page 6 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Section 2. Getting Started • Field assembly (if required) Install the JXi in accordance with the procedures in this • Appropriate site location, clearances and fl ooring manual, local codes and ordinances, and in accordance with the latest edition of the appropriate national code.
  • Page 7: Required Equipment

    Page 7 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Required Equipment Please ensure that the following equipment is available to the installer at the time of installation. 2.2.1 Tools Safety Eyewear...
  • Page 8: Section 3. Location Requirements

    Page 8 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Section 3. Location Requirements The JXi heater is shipped from the factory with an NOTE: If the heater is to be operated in below freezing conditions it exhaust vent confi gured for outdoor installation.
  • Page 9: Outdoor Installation

    Page 9 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Outdoor Installation Locate the heater: NOTE: In Canada the top of the exhaust vent must be at least 10 • On a level Solid Surface feet (3 m) from any building opening..
  • Page 10: Anchor Bracket Installation

    Page 10 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 3.2.1 Anchor Bracket Installation Anchor brackets do not come standard with the JXi if you Tighten the retaining nut so that the anchor bracket require the anchor brackets for your installation please assembly is secure.
  • Page 11: Indoor And Outdoor Shelter Installation

    This could cause fl ue products to accumulate in All outdoor the room. Additional air must be supplied 50 in shelter and JXi 200 323 cm to compensate for such exhaust. Consult indoor installations 65 in...
  • Page 12: Exhaust Venting

    Page 12 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 3.3.2 Exhaust Venting Horizontal runs must be sloped upwards away from When the JXi heater is installed indoors or in an outdoor •...
  • Page 13: Indoor And Outdoor Shelter Exhaust Conversion

    Page 13 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 3.3.3 Indoor and Outdoor Shelter Exhaust Conversion For both Category I and Category III vent types the heater must fi rst be converted to indoor exhaust type. In order to complete the conversion you will need to order exhaust conversion R-Kit R0711900.
  • Page 14: Indoor And Outdoor Shelter Exhaust Termination

    Page 14 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 3.3.4 Indoor and Outdoor Shelter Exhaust Termination Category I: Appliance must be vented vertically and a side wall. Side wall vents must be installed and located in accordance with the National Fuel Gas Code NFPA terminate at the roof.
  • Page 15: Section 4. Gas Connections

    Page 15 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Section 4. Gas Connections Gas piping installation must be in accordance with the latest edition of ANSI Z223.1 and all local codes. In...
  • Page 16: Inlet Gas Pressure Test

    Page 16 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Inlet Gas Pressure Test Remove manometer, hose and barbed fi tting from the Before operating the heater it is necessary to test the input •...
  • Page 17: Connect The Digital Differential Manometer

    Page 17 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 4.3.1 Connect the Digital Differential Manometer. Connect a tee to the hose running from the fan inlet port on the blower to the gas valve vent port.
  • Page 18: Special Precautions For Lp Gas

    (Suction Outlet) SPA RETURN MANUAL BYPASS VALVE MANUAL BY-PASS DETAIL: POOL USE WHEN FILTRATION RATE RETURN EXCEEDS 100 GPM FOR JANDY JXi HEATERS. REFER TO THE MANUFACTURER’S RECOMMENDATIONS IF USING A DIFFERENT BRAND HEATER. Typical Water Piping Confi guration Figure 7.
  • Page 19: Pump Sizing

    MODEL MIN GPM (LPM) MAX GPM (LPM) accommodate flow rates delivered to the heater from a minimum of 30 gallons per minute (gpm) to a maximum JXI 200 30 (114) 100 (379) flow of 100 gpm. JXI 260 30 (114)
  • Page 20: Plumbing Connections

    Section 5.1.1. • Turn off all power to the heater at the breaker. The top inlet is intended for use with the Jandy • Turn off main gas supply to heater. Versa Plumb ®...
  • Page 21: Water Pressure Switch Adjustment

    Page 21 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Install the union nut and drain cap with o-ring at the • Union Nut Sweep Elbow unused inlet on the heater manifold. Be sure that the o-ring is properly seated.
  • Page 22: Check Valve Installation

    A pressure relief valve is not supplied with the JXi heater. in ANSI Z21.22 for the United Sates or CSA 4.4 in ® However, Jandy does offer a PRV Kit # R0336101. The Canada. following instructions are for use with this kit only. All 5.5.1 Install pressure relief valve kit # R0336101 •...
  • Page 23: Auxiliary Components, Chlorinators, Ozone Generators, And Sanitizing Chemicals

    800.822.7933. Additional Always follow pool chemical manufacturer’s • information can be found at www.jandy.com. Be sure to adhere to the following: instructions when adding chemicals to pool. All sanitation equipment is to be installed as the last •...
  • Page 24: Section 6. Electrical Connections

    Page 24 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Section 6. Electrical Connections 6500 REV A (note) Wiring connections must be made exactly as shown in r inside front panel be in accordance with the latest edition of the National...
  • Page 25: Service Access

    Page 25 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Service Access Remove the four screws holding • the front heater panel in place to expose the raceway. Locate the raceway lock release on the interior of the heater raceway.
  • Page 26: Input Voltage And Conversion

    If you are setting up a new pool or spa system, or if you have any questions about your heater control system, Consult with Jandy Technical Support, 800.822.7933 for questions about installing non-Zodiac remote controls. please call Jandy technical support at 800.822.7933.
  • Page 27: Connecting To A Remote Pool-Off-Spa Selector (3-Wire Connection)

    Page 27 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Connecting to a Remote Pool-Off-Spa Selector (3-Wire Connection) Turn off the power to both the pool/spa control Connect the wiring from the pool/spa control system •...
  • Page 28: Smart" Communication Via Rs-485

    The wires coming from the heater can be “doubled which includes the Multiplex Board (part # 6584) must be up” on the red terminal bar with the four wires from used. Call Jandy Technical Support at 800.822.7933 with any questions. the indoor controller.
  • Page 29: To Restore Heater Control Panel Functionality After Connecting To An External Controller

    • Turn power to the heater ON. The heater display • Press MENU to remove message and restore shows: JANDY REMOTE ONLINE PUSH MENU functionality to the heater control panel. TO DISABLE . 7.3.2 To Return Control Back to a Connected External Controller Choose JANDY REMOTE.
  • Page 30: Operating Instructions

    Page 30 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH OPERATING INSTRUCTIONS 8.2.1 Refer to the Lighting and Shutdown Instructions. See Wait fi ve (5) minutes to clear out any gas, then smell •...
  • Page 31 Page 31 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result, WARNING causing property damage, personal injury, or death.
  • Page 32: Operating The Controller

    Page 32 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Operating the Controller Unless the heater is connected to a remote controller, all operations are set up and programmed through the control panel on the top of the heater. See...
  • Page 33: Operating The Heater

    Page 33 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH MENU 8.5.2 Operating the Heater If connected, the Maintain Heat mode monitors the pool water • To Turn on Pool or Spa Heat temperature 24 hours a day by turning the pool pump on and sampling the water temperature.
  • Page 34: Section 9. Maintenance

    Page 34 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Section 9. Maintenance If the heater is not going to be used for an extended balanced water please see Section 9.1.1 for complete period of time and in colder climates, shut it down details on managing your water chemistry.
  • Page 35: Swimming Pool Energy Saving Tips

    Page 35 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Swimming Pool Energy Saving Tips Please review the following recommendations to help • If the pool is only going to be used on weekends,...
  • Page 36: Inspection And Service

    • Inspect the inlet grill at the blower for blockage, as needed. Routine inspections are a critical to the safety leakage, and corrosion. and long life of your Jandy pool equipment. • Inspect the combustion blower for damage. • Check for loose or broken wires and terminal •...
  • Page 37: Section 10. Troubleshooting

    To locate a licensed or qualified occur when the heater is started for the first time after installation or at spring start-up. technician service company, call Jandy Technical Support at 800.822.7933, or visit www.jandy.com, Symptom...
  • Page 38: Service Diagnostic Messages

    Page 38 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 10.2 Service Diagnostic Messages The controller monitors several functions of the heater. Service Messages along with potential causes and In the event of a malfunction, the controller will display remedies.
  • Page 39: Section 11. Professional Service And Maintenance

    Page 39 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH Section 11. Professional Service and Maintenance Call a qualified service technician to perform all service and repairs on the heater. To locate a licensed or qualified...
  • Page 40: Cabinet Assembly Spare Parts List And Exploded Parts Diagram

    Page 40 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 12.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram Key No Description model 200 model 260 model 400 Heater Jacket Top Kit (no User Interface)
  • Page 41: Heat System Spare Parts List And Exploded Parts Diagrams

    Page 41 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 12.3 Heat System Spare Parts List and Exploded Parts Diagrams 12.3.1 Combustion Chamber Assembly Key No Description model 200 model 260 model 400...
  • Page 42: Burner Assembly

    Page 42 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 12.3.2 Burner Assembly model 200 model 260 model 400 Key No Description **LP Blower Assembly Kit R0591100 R0591100 R0591100 R0591100 R0591100 R0591100...
  • Page 43: Water System Spare Parts List And Exploded Parts Diagrams

    Page 43 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 12.4 Water System Spare Parts List and Exploded Parts Diagrams Key No Description model 200 model 260 model 400 Access Door Kit (with O-Ring Seal and Screws)
  • Page 44: Electrical System Spare Parts List And Exploded Parts Diagrams

    Page 44 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH 12.5 Electrical System Spare Parts List and Exploded Parts Diagrams Key No* Description model 200 model 260 model 400 Ignition Control Kit...
  • Page 45 Page 45 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH NOTES...
  • Page 46 Page 46 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH NOTES...
  • Page 47 Page 47 Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater Installation & Operation Manual ® ™ ENGLISH NOTES...
  • Page 48 Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 | www.jandy.com ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks referenced herein are the property of their respective owners. ©2016 Zodiac Pool Systems, Inc. H0404700_REVG...

This manual is also suitable for:

Jxi 260Jxi 400

Table of Contents