ENGLISH
7.3

Input Voltage and Conversion

The heater comes factory-wired for installation with 240
Volt, 60 Hz AC field electrical supply. If the use of 120
Volt, 60 Hz AC field electrical supply is required, You
must first change the position of the voltage selector
board on the power distribution board.
Ensure that all electrical power is shut off to the
heater at the breaker.
Ensure that the filter pump is off and will stay off for
the remainder of the procedure.
Follow service access instructions from
a
Locate the power distribution board in the lower right hand
section of the raceway.
b
Using scissors, clip the zip tie securing the voltage
selector board into the power
distribution board.
b
7.4

Bonding

In the United States the National Electrical Code
and in Canada the Canadian Electrical Code (CEC),
require that all metallic components of a pool structure,
including reinforcing steel, metal fittings and above
ground components be bonded together (forming an
equipotential bonding grid) with a solid copper conductor
not smaller than an 8 AWG (6 AWG in Canada).
Additionally, Zodiac Pool Systems LLC, requires that
the appliance be connected to a bonding loop that
includes all electrical equipment in the system and on
the equipment pad. Bonding lugs must be connected
with a solid copper wire at least 8 AWG (6 AWG
in Canada) or larger. Failure to do so will void the
Zodiac Pool Systems LLC warranty.
CAUTION
To prevent premature failure of the appliance resulting from stray
voltages and voltage differentials, the heater must be bonded to other
equipment which is part of the pool plumbing system with a solid
copper wire not smaller in diameter than 8 AWG (6 AWG) in Canada).
Jandy
, JXi
Gas-Fired Pool & Spa Heater
®
c
Remove and rotate the voltage selector board 180°. The
printed message "FOR 120 VAC" will be displayed above the
card connection pins.
d
Reinstall voltage selector board.
NOTE: The voltage selector board is keyed so that it will fit in only
one direction for either selected voltage (either side of the board).
Section
6.1.
ELECTRICAL SHOCK HAZARD. To avoid an electrical shock
hazard, which can result in serious injury or death, ensure that all
electrical power to the system is turned off before approaching,
inspecting, or troubleshooting any leaking plumbing that may have
caused electrical devices in the surrounding area to get wet.
a
c
(NEC
)
®
®
National Electrical Code
of the Pool Water. Where none of the bonded
pool equipment, structures, or parts are in direct
connection with the pool water; the pool water shall
be in direct contact with an approved corrosion-
resistant conductive surface that exposes not less
than 5800 mm² (9 in²) of the surface area to the pool
water at all times. The conductive surface shall be
located where it is not exposed to physical damage
or dislodgement during usual pool activities, and
it shall be bonded in accordance with the bonding
requirements of NEC Article 680. Refer to
locally enforced codes for any additional bonding
requirements.
|
Installation & Operation Manual
WARNING
d
(NEC
) requires bonding
®
®