Jandy HI-E2 Installation And Operational Manual

Jandy HI-E2 Installation And Operational Manual

Pro series. gas-fired pool and spa heater ehe
Table of Contents

Advertisement

Jandy Pro Series Hi-E
WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in
which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or
maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow
warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation can create carbon
monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety,
Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent
occupied spaces. Improper installation and/or operation will void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Gas-Fired Pool and Spa Heater
IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY,
A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY
DAMAGE, PERSONAL INJURY, OR DEATH.
INSTALLATION AND
OPERATION MANUAL
and Hi-E
®
2
R
®
2
EHE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI-E2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jandy HI-E2

  • Page 1 INSTALLATION AND OPERATION MANUAL Jandy Pro Series Hi-E and Hi-E ® ® Gas-Fired Pool and Spa Heater IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY WARNING DAMAGE, PERSONAL INJURY, OR DEATH. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists.
  • Page 3: Table Of Contents

    Page 3 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Table of Contents Section 1. General Information ....... 4 Water Chemistry ..........21 3.4.1 Pools ............21 Introduction ............4 3.4.2 Spas ............21 Description ............
  • Page 4: Section 1. General Information

    35,000 ppm range. In Canada, install the heater in accordance with local For special applications, consult your Jandy Pro Series codes and the most recent edition of the Natural Gas and dealer.
  • Page 5: Heater Assembly And Preparation

    Page 5 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® When pool equipment is located below the pool surface, WARNING a leak from any component can cause large scale water loss or flooding. Zodiac Pool Systems, Inc. cannot be...
  • Page 6: Outdoor Shelter Installation (Canada)

    Page 6 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® 1/4” X 2-1/4” GALVANIZED OR PLATED CONCRETE SCREWS Figure 2. Anchor heater to equipment pad. each of the holes and fasten the heater to the equipment pad, see Figure 2.
  • Page 7: Combustion Air Requirements For One-Pipe Installation

    Page 7 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® The necessary vent collar, gasket and screws are shipped and one (1) near the floor. When air is provided directly packaged within the heater. The conversion can be done through an outside wall, each opening must have at least quite simply as follows.
  • Page 8 Page 8 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Total Length: 42' Total Elbows: 5 EHE350 Figure 5. Connection of combustion air pipe to heater. 2.7.3.2 Piping Materials Figure 6. “One-pipe” installation.
  • Page 9 (See Fig. 10) Elbow Combustion Air Pipe Figure 7. Indoor vent connection, Hi-E2 pool heater. 18" min. 60" max five (5) elbows. Per Table 3, Only 16 feet of 4" vent pipe would be allowable which would not allow for completion of the run.
  • Page 10: Condensate Disposal

    Page 10 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® for such use. Joints in 29-4C stainless steel pipe must ® be sealed in accordance with its listing. Connection of combustion air and vent piping to the heater should be...
  • Page 11: Gas Supply And Piping

    Page 11 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® of condensate can be produced in an hour. Condensate is Condensate From mildly acidic. Before treatment, its “pH” is typically in the Vent/Blower Drains 3.5 to 6.0 range.
  • Page 12: Special Precautions For Lp Gas

    Page 12 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Table 4. Gas Supply Pressure Requirements. Supply Pressure Minimum Maximum Natural Gas 5 inches WC 10.5 inches WC (125 mm WC) (265 mm WC)
  • Page 13: Bonding

    électriques à tolérance nominale de 105°C. GAS VALVE Soupage de gaz DIGITAL IGNITION CONTROL H0205500F Figure 15. Wiring diagram, Hi-E2 pool heater. The Hi-E requires electrical power from a 115V, 60 Hz 2.10.2 Bonding source. Do not connect this heater to a 230VAC power CAUTION source.
  • Page 14: Auxiliary Time Clock Wiring

    ® remote control permits switching from pool to spa, with temperature set points for each, and turning the heater on and off from a remote location. Contact your local Jandy Pro Series distributor for information on the AquaLink ® RS control system to fit your back yard recreational needs.
  • Page 15: Water Piping

    Page 15 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® AQUAPURE MANUAL BY-PASS DETAIL MANUAL BY-PASS IS USED WHEN FILTRATION RATE EXCEEDS 125 GPM Figure 20. Typical water piping. 2.11 Water Piping Remove both headers by unscrewing eight (8) cap screws retaining each header.
  • Page 16: Connections At Heater

    Page 16 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® pool surface a leak can result in large scale water loss or Method For Installing flooding. Zodiac cannot be responsible for such water loss Any Threaded Pipe or flooding or the damage caused by it.
  • Page 17: Automatic Chlorinators

    Page 17 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® The maximum working pressure of this heater is 75 energizes a “hot surface” igniter. psig. Be sure to take into consideration the maximum...
  • Page 18: Condensate

    To avoid this "wet" start-up, simply pour water pool surface and no more than ten feet below it. For other into the tray before starting the heater. situations, contact a Jandy Pro Series representative. CAUTION 2.12.4 Gas Pressure...
  • Page 19: Water Temperature Rise

    Page 19 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® inside the heater. Remove the brass plug on the top surface of the header and install a Pete's Plug and pocket thermometer. See Figure 25.
  • Page 20: Section 3. Operating Instructions

    Page 20 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Section 3. Operating With any new pool or spa installation, run the filter pump with the heater off long enough to completely clean the Instructions water.
  • Page 21: Shutdown

    Page 21 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Water Chemistry Jandy 3.4.1 Pools The mineral content of swimming pool water increases daily, due to natural evaporation and the addition of sanitizing chemicals. If the mineral concentration in the...
  • Page 22: Spa/Hot Tub Safety Rules

    Page 22 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® 3.4.2.2 Saturation Index 3.4.2.3 Water Changing PH, Total Alkalinity (TA), temperature, Calcium Hardness Zodiac Pool Systems, Inc. recommends changing of and Total Dissolved Solids (TDS) play a role in whether spa water every 60 days if usage is light and every 30 the water is either corrosive or scale forming.
  • Page 23: Swimming Pool Energy Savings Tips

    Page 23 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Prolonged immersion in hot water can induce Seasonal Care hyperthermia. Hyperthermia occurs when the internal body temperature reaches a level several degrees above 3.7.1...
  • Page 24: Periodic Inspection

    Page 24 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® To reactivate the heater in the spring, have a qualified neutralizer and enough water to create a water professional technician reassemble the heater as follows: trap in the condensate drain assembly.
  • Page 25: Section 4. Maintenance And Service

    SERVICING SAFETY Heater Components and Their Some of the servicing procedures for the HI-E2 heater are hazardous because they involve fuel gas, Operation electricity, moving parts and procedures which require Gas valve / Regulator - The gas valve controls testing or temporary bypass of safety controls.
  • Page 26: Combustion Air Filter

    Replace it only with the specified part the ignitor. available from a Jandy Pro Series representative. Push the replacement filter into the tracks and slide the panel back in. Venturi Pressure Switch - This switch verifies...
  • Page 27: Electrical Trouble Shooting

    Page 27 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Electrical Trouble Shooting measurements. Location numbers in circles have been added, and will be referenced in the following sections. WARNING As stated at the beginning of this manual, some of these ELECTRICAL SHOCK HAZARD.
  • Page 28 Page 28 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Absence of voltage at point 6 indicates that the control is 4.5.2.3 Fireman Switch and External not calling for heat. Be sure that knobs are set to call for...
  • Page 29: Venturi Combustion Flow System

    Page 29 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® To trouble shoot the ignition control, connect the voltmeter 4.5.2.11 Combustion Blower probe at point 8 and set the control to call for heat. Observe...
  • Page 30: Pressure Measurement Ports

    Page 30 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Connect the positive side of the manometer to the venturi 4.6.1 Pressure Measurement Ports inlet service port, which is at the bottom on the right Figure 33 shows venturi and gas control components side.
  • Page 31: Air Flow Investigation

    Page 31 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® 4.6.3 Air Flow Investigation If gas pressure offset is correctly set but gas orifice differential is abnormal, check air flow through the system per the following sections.
  • Page 32: Fuel Gas Type And Gas Orifice Size

    Consult heater, the pressure will be 0.2 to 0.6" WC less than your Jandy Pro Series representative if the available gas is the ambient pressure. For a model 350 with clean filter substantially different.
  • Page 33: Combustion Condensate

    The Hi-E2 pool heater is certified for use indoors or outdoors in the United States. • The Hi-E2 pool heater is for use with natural or liquefied petroleum gas. Ratings apply to either fuel. • De-rating for elevation is not necessary because of the Hi-E2 heater's special combustion system.
  • Page 34: Section 6. Replacement Parts

    Section 6. Replacement Parts Ordering Information To order or purchase parts for the Jandy Pro Series Hi-E pool and spa heater, contact your nearest Zodiac dealer or distributor. Access the Zodiac web site at www.zodiacpoolsystems.com for the nearest service center. If it cannot supply you with what you need, contact Zodiac Pool Systems, Inc.
  • Page 35 R0319405 High Temp. Silicone Sealant R0322800 EXHAUST ASSEMBLY Heat Exchange Baffles 350 R0410100 49 Blower/Collector Gasket R0308700 4" Venting Connector, Hi-E2 R0444900 50 Combustion Blower R0308200 51 Blower/Vent Duct Sleeve R0308600 52 Blower/ Vent Duct Clamp R0308800 53 Vent Duct Assembly R0303100...
  • Page 36: Exploded View

    Page 36 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® Exploded View 83-84 65,66 32,33 13 16 68-70 18-23 51,52 24-28 75-81 58-60 72-74...
  • Page 37 Page 37 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® NOTES...
  • Page 38 Page 38 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® NOTES...
  • Page 39 Page 39 ENGLISH Jandy Pro Series, Hi-E2 and Hi-E2R Gas-Fired Heater Installation & Operation Manual ® ® NOTES...
  • Page 40 Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 | www.jandy.com ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks referenced herein are the property of their respective owners. ©2017 Zodiac Pool Systems, Inc. H0205000_REVL...

This manual is also suitable for:

Hi-e2r

Table of Contents