ATTACHMENTS AND OPTIONS
METHOD FOR SETTING PCS
1.
Press menu switch (1) and enter the setting mode.
2.
Select "Attachment Setting" on "Machine Setting or Infor-
mation" menu, and press ENTER switch (2).
If the flow rate mode and maximum flow rate are set al-
ready, select any setting, and the setting is completed.
If you press menu switch (1) at this time, you can change
the setting of the selected attachment.
You can save up to 5 settings.
3.
To change the setting name, select "Attachment Name"
and press ENTER switch (2).
Change the alphabet at the cursor with UP or DOWN
switches and move the cursor with menu switch (1).
After completing the change, press ENTER switch (2).
HANDLE MULTIFUNCTION MONO-LEVER
6-9