Komatsu WA480-8 Operation & Maintenance Manual page 139

Wheel loader
Table of Contents

Advertisement

OPERATION
2.
Press ENTER switch (1) to reset or press RETURN switch
(2) to cancel resetting.
AUTO IDLE STOP TIMER SETTING
Stops the engine automatically when the idle state continued for a predetermined time.
The auto idle stop works only when all of the following conditions are met.
The engine is running normally.
The machine is stopped.
The accelerator pedal is not depressed.
The transmission is in NEUTRAL (N).
The engine is not in warm-up operation.
The engine coolant and hydraulic oil are not overheating.
Aftertreatment devices are not in regeneration.
The parts of DEF system are not in thawing control mode.
1.
Select "Auto Idle Stop Timer Setting" on "Machine Setting
and Information" menu, and press ENTER switch (1).
EXPLANATION OF COMPONENTS
3-71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents