ETC Installation Guide
ColorSource Spot v1.7
Error Codes
There are three error codes that may be shown on the user interface.
CAL
•
the color calibration. The fixture will need to be returned to the ETC
factory; contact your local dealer to set up a repair.
OtP
•
has gone into over-temperature protection mode to avoid damaging
the fixture. Once the fixture has self-cooled, the error will automatically
clear.
No App
•
upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.
RDM Values
Parameter
Manufacturer ID
Model ID
DMX Start
Address
DMX Personality
Output Frequency All
ColorSource Spot
: Screen toggles between
: Screen toggles between
: Screen toggles between
Fixture
All
ColorSource Spot
ColorSource Spot
Deep Blue
All
All
CAL
ERR
and
to indicate a problem with
OtP
ERR
and
to indicate that the fixture
no
APP
and
Value
0x6574
0x0205
0x0206
0x00F0 Range = 1–512
0x00E0
0x8123
Page 11 of 12
to indicate that the
Description
Electronic Theatre
Controls
1 = 5 Channel
2 = Direct
3 = 1 Channel
4 = RGB
0 = Standard (1.2 kHz)
1 = High (25 kHz)
ETC
Need help?
Do you have a question about the ColorSource Spot and is the answer not in the manual?