INSTRUCTION MANUAL
If the guide pipe holder is attached directly to the concrete, use hole-in anchor bolt as
shown in Fig. 3.
CAUTION : IF THE CABLE LEAD-OUT ELBOW IS TOO SMALL IN DIAMETER,
!
THE CABLE MAY BE HEATED WHERE IT RUNS THROUGH THE ELBOW.
3.3 Discharge Elbow Installation (Fig. 4)
WARNING : WHEN LIFTING THE PUMP, USE APPROPRIATE CRANE (OR
!
HOIST) AND LIFT SYSTEM.
CHECK POSITION AND TIGHTNESS OF LIFT SYSTEM SO THAT WEIGHT OF
THE PUMP IS NOT UNBALANCED.
FAILURE TO OBSERVE THIS PRECAUTION CAN RESULT IN SERIOUS
ACCIDENTS.
Install the discharge elbow level on the bottom on the pump pit, and connect the
guide pipe.
PM32U
Hole-in anchor bolt
Fig. 2
P.3