The motor shaft is sealed with a mechanical seal. The coolant chamber provided
between the two sealing stages can be filled with coolant by standing the pump
vertically and unplugging "Coolant supply hole" and "Air vent & full level check hole".
CAUTION : THE SEAL CHAMBER MAY BE UNDER PRESSURE. HOLD A
!
RAG OVER THE PLUG TO PREVENT SPLATTER.
Pour the specified coolant into the coolant chamber through "Coolant supply hole"
until the coolant flows out of "Air vent & full level check hole". (See Table 1c)
After the coolant chamber is filled to the specified level, plug the two holes.