Download Print this page

EBARA DSC4 Series Operating Instructions, Installation & Maintenance Manual page 32

Submersible wastewater, sewage pump

Advertisement

INSTRUCTION MANUAL
(2) Protect surfaces of mating flanges and the corners of spigot and socket.
(3) Cover the shaft threads to protect from damage after disassembly.
(4) After disassembly, apply temporary rust prevention to the machined surfaces
such as lifted surfaces, threads, shafts, etc.
(5) Be careful not to drop tools and parts into the sump pit.
(6) To protect against lost parts and mixing of parts with those from another
machine, provide cases for disassembled parts and store parts in cases.
(7) Store bolts in bags as a set.
(8) Do not disassembly the motor. If the motor requires disassembly, please
contact us.
6.6 Replacing Components
(1) Changing oil
Stand the pump in a vertical position, and unplug "oil drain" and "air vent".
Drain all oil from the "oil drain" (In case of model "F","G","D1","D2","G1" and
"G2" using the oil pump.)
Inspect the oil for water contamination. If the oil contains much water,
mechanical seal must be replaced.
After the oil has been inspected, pour oil (Turbine Oil ISO VG 32) through the
"oil port", until oil overflows from "air vent".
Put a sheet gasket between the plug and the boss, and tighten the plug.
(Refer to Para. 3.6.1)
PM32U
Fig. 22
P.31

Advertisement