To verify the performance of the emulator
1 If you have a special configuration or session in progress, save it now. This
procedure will cause your session to be lost.
2 Turn off power to the HP 64700 Card Cage.
3 Plug the emulator probe into the Demo Board. (See Chapter 3.) Your target
system cannot be used for running performance verification.
4 Connect Demo Board power cable from the Demo Board to the HP 64700
Card Cage front panel. (See page 19.)
5 Make sure an appropriate clock module is installed.
6 Turn on power to the HP 64700 Card Cage.
7 Establish communication with the emulator from your host or ASCII terminal and
obtain a prompt (such as R>). (See Chapter 3.)
8 Enter: pv 1 <return>
There are different hardware system configurations for the HP 64700 Series
system. For information on hardware configurations, refer to the HP 64700
Installation/Service manual.
Note that PV (performance verification) is affected by your choice of a clock
module, as follows:
•
If you run PV with the Target Oscillator Clock Module or Module C or E
installed, performance will be verified but only for the clock mode associated
with the module installed.
•
If you run PV with Module B or D installed, or with no module installed, PV
will fail. You must install one of the other clock modules to run PV.
•
If you wish to run PV to test all possible modes of emulator operation, install
Module A. After using Module A for PV, remove it and install the module
Chapter 6: Solving Problems
To verify the performance of the emulator
111