Maintenance
7.4.3 Variant of "Force amplification cylinder" (KVZ) without
38
09.00 | PWG-plus | Assembly and operating manual | en | 389495
maintenance of gripping force
Position of the item numbers:
cylinder
[
 48]
}
Remove compressed air lines.
Ø
Remove the cover (6).
Ø
Unscrew the screws (41) and remove the cover (8).
Ø
Unscrew the screw (40) and remove the cylinder piston (60) and
Ø
the spacer piston (66) from the intermediate housing (65).
Unscrew the screws (46) and remove the intermediate housing
Ø
(65).
Remove the second cylinder piston (7) from the housing (1).
Ø
Loosen set-screws (21) in the base jaws (2).
Ø
Remove the bolt (5).
Ø
Pull the base jaws (2) out of the housing (1).
Ø
Push the piston assembly (3, 4 and 39) upwards out of the
Ø
housing (1).