2 LOCATION - GENERAL
2.11
2.12 Protection: The pump must be located in a dry position, frost free
2.13 Ventilation: Ensure an adequate air flow to cool the pump.
2.14 Safety: The motor casing can become very hot under normal
2.15 Water retention: Site the pump in a location where in the unlikely
2.16 Pump position: The pump must be positioned on its mounting feet and as
close to the water source as possible.
2.17 Mounting foot securing: This pump is fitted with steel feet. If there is a
requirement to secure the pump via the feet, the following points should be
noted.
The pump should be mounted only in the horizontal position.
The mounting bolts used to secure the pump must be fitted with a plain
washer to distribute clamping load evenly across load bearing face of foot
(not supplied).
MOUNTING
FOOT
Access: For emergencies and maintenance the pump must be
easily accessible.
and protected from freezing.
Separate the pump from other appliances that generate heat. An
80 mm (3 ") air gap must be maintained around the pump.
operating conditions. Care must be taken to ensure it cannot be
touched during operation.
event of a water leak, any spillage is contained or routed to avoid
electrics or areas sensitive to water damage.
Fig. 2
PLAIN
WASHER
BOLT
Fig. 3
- 7 -