Worth Data RF Terminal 7000 Owner's Manual page 57

Host controlled rf terminal system
Hide thumbs Also See for RF Terminal 7000:
Table of Contents

Advertisement

Function:
This instructs the
data to be received through the terminal serial port. Waiting for serial input can be
bypassed by pressing the enter key on the terminal which will send an empty data string
to the host (fires the
OutputSerial
Parameters: data
Function:
This instructs the
than 231 characters in length for each call to
SendDisplay
Parameters: line, position, prompt
SendDisplayColor (15-line terminal only)
Parameters: line, position, prompt,FG,BG
Function:
This instructs the
followed by an "
ClearScreen
Function:
This instructs the
method call to take effect.
ClearLine
Parameters: line
Function:
This instructs the
indicated by 1-9 and A-F Must be followed by an "
DefineFormat (15-line terminal only)
Parameters: font, linecount
Function:
Adds a line formatting definition. This command is called multiple times to build a
display formatting definition for multiple lines which is then sent to the
the SendFormat command.
If only one line is defined (that is DefineFormat is called only once), then after
SendFormat is called, only one line will be available for display on the ActiveTerminal.
There are a limited number of lines available depending on the font size(s) chosen. Each
font has a defined height:
The total height of the defined lines cannot exceed 240. If it does, an error code is
generated (see CheckError) and the SendFormat command is ignored.
There is limited display width available for text. Depending on the font you select for a
line:
If you try to send prompt or display text longer than this, it will be truncated and an
error code is generated (see CheckError).
Must be followed by a SendFormat and then an Input call to take effect.
ActiveTerminal
OnTermData
ActiveTerminal
ActiveTerminal
" method call to take effect.
Input
ActiveTerminal
ActiveTerminal
small: 16
medium: 24
large: 32
small: 26 characters
medium: 20 characters
large: 13 characters
to display the prompt at line and position and wait for
event handler).
to send data to the terminal's serial port. Data must be less
OutputSerial
to display the prompt at line and position. Must be
to clear its display. Must be followed by an "
to clear the specified line on its display. Line number is
Input
.
" method call to take effect.
ActiveTerminal
"
Input
by

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RF Terminal 7000 and is the answer not in the manual?

Related Products for Worth Data RF Terminal 7000

This manual is also suitable for:

7000 series

Table of Contents

Save PDF