3500/42 Operation and Maintenance
Pass Main Board -24V-A
Event Number: 113
Event Classification: Potential Problem
Action: Verify that noise from the power source is not causing the problem. If
Fail Main Board -24V-B
Event Number: 114
Event Classification: Potential Problem
Action: Verify that noise from the power source is not causing the problem. If
Pass Main Board -24V-B
Event Number: 115
Event Classification: Potential Problem
Action: Verify that noise from the power source is not causing the problem. If
* Fail Main Board -24V-AB
Event Number: 116
Event Classification: Severe/Fatal Event
Action: Verify that noise from the power source is not causing the problem. If
Pass Main Board -24V-AB
Event Number: 117
Event Classification: Severe/Fatal Event
Action: Verify that noise from the power source is not causing the problem. If
(Pass Main Board -24V - upper Power Supply)
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the upper slot
(Fail Main Board -24V - lower Power Supply)
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the lower slot
(Pass Main Board -24V - lower Power Supply)
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the lower slot
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the upper slot
- the Power Supply installed in the lower slot
Monitor Module will stop alarming.
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the upper slot
- the Power Supply installed in the lower slot
(Fail Main Board -24V - upper and lower
Power Supplies)
(Pass Main Board -24V - upper and lower
Power Supplies)