Siemens SITRANS AS100 Operating Instructions Manual

Acoustic sensors
Hide thumbs Also See for SITRANS AS100:

Advertisement

Bufferzone
The image must not touch with the Bufferzone.
Background coolgray 20%, without history
8 mm
Acoustic Sensors
SITRANS AS100
8 mm
Operating Instructions
A text area at the top is (big bar) 2-Spaltig, so the text extends upwards!
Then adjust the transparent beams according to and while holding the
8 mm distance from text.
I think this means that, if you need to add more lines of text, extend the big
bar upwards, while maintaining the proper distance from the text.
The lower pane (smal bar, Dokuklasse) must be only single-column!
Title page without bleed
in RGB
Find any font sizes for the text fields in the
Panel "Paragraph styles"!
Image should come behind the bar so that
the transparency comes to the fore.
Do not change the transparency of the bar!
Siemens Serif OT, Semibold, 36/30/26 PT, weiss
Absatzformat: 01 System 36/30/26 pt
Siemens Sans OT, Bold, 18/15/13 PT, weiss
Absatzformat: 02 Produkt 18/15/13 pt
Siemens Sans OT, Bold, 13/11 PT, weiss
Absatzformat: 03 Titel 13/11 pt
Siemens Sans OT, Bold, 13 PT, weiss
Absatzformat: 04 Dokuklasse 13 pt
Natural Blue dark CoolGray 100%
Edition
Siemens Sans OT, Bold, 11/7,5 pt, weiss
Absatzformat: 05 Ausgabe 11/7,5 pt
Siemens Sans OT, Bold, 13 PT, schwarz
Absatzformat: 06 SectorClaim 13 pt
06/2016

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS AS100

  • Page 1 Background coolgray 20%, without history Image should come behind the bar so that the transparency comes to the fore. Do not change the transparency of the bar! Siemens Serif OT, Semibold, 36/30/26 PT, weiss Absatzformat: 01 System 36/30/26 pt 8 mm Acoustic Sensors...
  • Page 2 • For a selection of Siemens level measurement manuals, go to: Level Measurement. www. siemens.com/processautomation. Select Products & Systems, then under Process Instrumentation, select Manual archives can be found on the Support page by product family. • For a selection of Siemens weighing manuals, go to: Weighing and Batching Systems.
  • Page 3 General Information ___________________ Specifications ___________________ Outline and Dimensions ___________________ Installation ___________________ Acoustic Sensors SITRANS AS100 Mounting ___________________ Interconnection ___________________ Operating Instructions Applications ___________________ 06/2016 A5E31952194-AB...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents General Information ..........................5 Specifications ............................7 Outline and Dimensions .......................... 9 Installation ............................15 Mounting ............................... 17 Interconnection ............................. 21 Applications ............................25 Index..............................29 SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 6 Table of contents SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 7: General Information

    Note • The SITRANS AS100 is to be used only in the manner outlined in this manual • This product is intended for use in industrial areas. Operation of this equipment in a...
  • Page 8 General Information SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 9: Specifications

    Available only for CSA Class II version Not available for hazardous rated versions Relative Sensitivity • 0.5% / °C of reading, average over the operating range Output • analog, 0.08 to 10 V DC nominal, 100 KΩ minimum load impedance SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 10 • Standards: 60079-0 : 2009, EN 60079-1 : 2007 and EN 60079-31 : 2009 ATEX II 3D FM Class II, Div. 1, Groups E, F, G Canada: CSA Class II, Div. 1, Groups E, F, G SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 11: Outline And Dimensions

    Outline and Dimensions SITRANS AS100 (ST and ET versions) ① 6 x 24 AWG cable ② Mounting post, 17A/F nut and M10 thread SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 12 Outline and Dimensions SITRANS AS100 (CSA/FM Class II Rated ST and ET versions) ① 6 x 24 AWG cable ② ½" NPT (CSA and FM approvals) or M20 (ATEX approval) female conduit fitting ③ Mounting post, 17A/F nut and M10 thread...
  • Page 13 Outline and Dimensions SITRANS AS100 (ATEX II 2GD version) WARNING Do not open when an explosive atmosphere is present. Possible static hazard. Do not rub or clean the product on site. ① Cable entry (2) M20 x 1.5 ② Enclosure...
  • Page 14 Outline and Dimensions Accessories Extension Tab (optional, not available for ATEX II 2GD version) ① SITRANS AS100 mounting hole M10 thread ② Bolt hole, 14mm (0.55")Ø SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 15 Outline and Dimensions Mounting Disc (optional, not available for ATEX II 2GD version) ① SITRANS AS100 mounting hole M10 thread Note Both Tab and Disc are 304SS. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 16 Outline and Dimensions SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 17: Installation

    ● joints and interfaces attenuate the acoustic emission levels. ● minimal temperature variation where acoustic emission levels are weak. ● location should provide sufficient response time in alarm or control circuit. e.g. loss of bearing lubrication, plug chute detection. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 18 Good friction between product and pip- Minimal amount of acoustic emission ing. Mount Sensor on the upstream side activity due to limited friction between of gasket for highest level of acoustic product and piping. emission activity. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 19: Mounting

    Mounting Note • To ensure the most ideal location, test the SITRANS AS100 by clamping the Sensor to the application, and running a trial period to determine the system's performance. The acoustic emission level can be monitored by a voltmeter across the analog output. Refer to Interconnection (Page 21).
  • Page 20 • If welding, weld must be a continuous bead. Tacking does not provide sufficient acoustical coupling. • Do not arc weld on equipent connected to a SITRANS AS100. Remove the SITRANS AS100 or disconnect electrically to avoid current flowing through the sensor.
  • Page 21 7. Install the sleeve over the tapered steel part, and thread the remaining two parts of the gland onto the cable. 8. Tighten the assembly to ensure a seal of the gland over the cable with outer jacket. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 22 For standard Temperature range model, If the flange temperature is 100°C and the maximum temperature is 80°C. ambient temperature is 20°C, the Sensor temperature at the electronics is below the maximum rating. *maximum range dependent on model. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 23: Interconnection

    Interconnection SITRANS AS100 Standard Temperature Version (ST) ① Vsup: 20 to 30 V DC supply input ② Vsens: analog output 0.08 to 10 V DC nominal ③ shield--tied to Sensor casing *Sensor range selection high sensitivity range = red and green to Vsup +...
  • Page 24 Maximum distance between Sensor and supply (24V or Control Unit) wire size distance meters feet 7 x 0.20 0.22 1600 7 x 0.25 0.35 2600 10 x 0.25 1200 3900 * nominal wire size SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 25 However, it is important to be aware of the effect. The sensitivity of the SITRANS AS100 Sensor decreases with increasing temperatures at a rate of approximately 0.5% per degree Celsius.
  • Page 26 Interconnection SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 27: Applications

    Sensor, an alarm in the control room informs the operator of a possible blockage. Recommended location is any point along the under side of chute, where there is friction due to the flow of material. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 28 Sensor mounted to each leg of the diverter indicates the presence or absence of flow in the open leg. Low alarm gives early indication of problems in the diverter gate or slide gate, or of blockage or material shortage in the hopper. Leak detection SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 29 Applications Cavitation Monitoring Install the SITRANS AS100 Sensor in B either A or B locations. Machine Condition Monitoring Install the SITRANS AS100 Sensor in either A or B locations. SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 30 2015 2016 2017 2018 2019 ALPHA CODE Month of Manufacture (one character alpha or numeric entry) Jan. Feb. Mar. Apr. Jun. Jul. Aug. Sept. Oct. Nov. Dec. Day of Manufacture (two character numerical entry) SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 31: Index

    Screw Conveyor Discharge, 25 Accessory Mounting, 18 SITRANS AS100 (ATEX II 2GD version), 11 Analog Output, 23 SITRANS AS100 (CSA/FM Class II Rated ST and ET versions), 10 SITRANS AS100 (ST and ET versions), 9 SITRANS AS100 Sensor, 5 SITRANS AS100 Standard Temperature Version...
  • Page 32 Index SITRANS AS100 Operating Instructions, 06/2016, A5E31952194-AB...
  • Page 34: For More Information

    Find any font sizes for the text fields in the Panel "Paragraph styles"! Background coolgray 100 %, Siemens Sans OT, Bold, 13 PT, schwarz Absatzformat: 01 Weitere Info 13 pt Siemens Sans OT, Roman, 9 PT, schwarz Absatzformat: 01 Info Text 9 pt...