System Requirements - Peak PCAN-PC/104-Plus User Manual

Can interface for pc/104-plus
Hide thumbs Also See for PCAN-PC/104-Plus:
Table of Contents

Advertisement

PCAN-PC/104-Plus – User Manual
Connection to CAN bus through D-Sub slot bracket,
9-pin (in accordance with CiA® 303-1)
NXP SJA1000 CAN controller, 16 MHz clock frequency
NXP PCA82C251 CAN transceiver
5-Volt supply to the CAN connection can be connected through a
solder jumper, e.g. for external bus converters
Galvanic isolation on the CAN connection up to 500 V (only
opto-decoupled versions), separate for each CAN channel
Extended operating temperature range from -40 to 85 °C
(-40 to 185 °F)
Optionally available: PCI/104-ISA stack-through connector
Note: This manual describes the use of the PCAN-PC/104-Plus
card with Windows. You can find device drivers for Linux and
the corresponding application information on the provided DVD
in the directory branch Develop and on our website under
www.peak-system.com/linux.
1.2

System Requirements

PC/104 stack with PCI-Bus (according to the specification PC/104-
Plus)
Operating system Windows 10, 8.1, 7 (32/64-bit)
or Windows CE 6.x (x86 and ARMv4 processor support)
or Linux (32/64-bit)
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipeh-002094Ipeh-002095Ipeh-002096Ipeh-002097

Table of Contents