  • Page 1 USER MANUAL ENGLISH Dataflower Product code: 43168 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2 Dataflower Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
  • Page 3: Table Of Contents

    Dataflower Table of contents Introduction ................................4 Before Using the Product ..........................4 Intended Use ............................... 4 Product Lifespan ..............................4 LEDs Lifespan ............................... 4 Text Conventions ..............................4 Symbols and Signal Words ..........................5 Symbols on the Information Label ........................5 Safety ..................................
  • Page 4 Dataflower Fixture Hours .............................27 Version ..............................27 Offset Mode ............................27 DMX Channels ..............................28 2 Channels ..............................28 5 Channels, 7 Channels ..........................28 Gobo Wheel and Color Wheel........................30 Troubleshooting ..............................31 Maintenance ..............................32 Safety Instructions for Maintenance ......................32 Preventive Maintenance ..........................32 Basic Cleaning Instructions ........................33 Corrective Maintenance ..........................33...
  • Page 5: Introduction

    After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec Dataflower ● Schuko to IEC (C13) power cable ● User manual Fig. 01 Intended Use This device is intended for professional use as a stage light effect.
  • Page 6: Symbols And Signal Words

    Dataflower Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in DANGER death or serious injury.
  • Page 7: Safety

    Dataflower Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions...
  • Page 8 Dataflower WARNING Risk of burns due to hot surface The surface and the inner parts of the device can become very hot during operation. ● Do not touch the device during operation. ● Allow the device to cool down for at least 15 minutes before handling.
  • Page 9: Requirements For The User

    Dataflower ● If the device is exposed to extreme temperature variations (e.g. after transportation), do not switch it on immediately. Let the device reach room temperature before switching it on, otherwise it may be damaged by the formed condensation. ●...
  • Page 10: Description Of The Device

    Dataflower Description of the Device The Showtec Dataflower is a stage light effect suitable for projection of gobo patterns on walls or dance floors. In combination with smoke or haze, it produces stunning aerial effects. Vivid colors and an optimized selection of gobos make Dataflower the ideal device for various gigs.
  • Page 11: Back View

    Dataflower Back View Fig. 03 3-pin DMX connector OUT 3-pin DMX connector IN Fuse T2AL, 250 V IEC (C14) power connector IN, 100–240 V, 10 A, 50/60 Hz IEC (C13) power connector OUT, 100–240 V, 8 A, 50/60 Hz Safety eye...
  • Page 12: Product Specifications

    Dataflower Product Specifications Model: Dataflower Electrical: Input voltage: 100–240 V AC, 50/60 Hz Power consumption: 117 W Fuse: T2AL, 250 V Physical: Dimensions: 308 x 265 x 202 mm (L x W x H) Weight: 3,8 kg Optics: Light source:...
  • Page 13: Dimensions

    Dataflower Dimensions Fig. 04 Fig. 05 Product code: 43168...
  • Page 14: Installation

    Dataflower Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons. Follow all applicable European, national and local safety regulations concerning rigging and trussing.
  • Page 15: Angle Adjustment

    Dataflower To mount the device, follow the steps below: Use a clamp to attach the device to the supporting structure, as shown in Fig. 06. Make sure that the device cannot move freely. Secure the device with a secondary suspension, for example a safety cable. Make sure that the secondary suspension can hold 10 times the weight of the device.
  • Page 16: Focus Adjustment

    Dataflower Focus Adjustment Turn the lens (03) clockwise or counterclockwise to adjust the focus. Fig. 08 Product code: 43168...
  • Page 17: Connecting To Power Supply

    ● Do not link more devices on one power link than the maximum recommended number. Maximum recommended number of devices: ● at 100–120 V: 8 devices Dataflower ● at 200–240 V: 15 devices Dataflower Product code: 43168...
  • Page 18: Setup

    Disconnect power supply before connecting or disconnecting data cables. Stand-alone Setup When the Dataflower is not connected to a controller or to other devices, it functions as a stand-alone device. It can be operated manually, in auto mode or in sound-controlled mode.
  • Page 19: Dmx Cables

    Fig. 09. Fig. 09 Master/Slave Setup The Dataflower supports master/slave control mode. To connect multiple devices in master/slave setup, follow the steps below: Connect the first device’s DMX OUT connector to the second device’s DMX IN connector with a 3-pin DMX cable.
  • Page 20: Dmx Linking

    Continue assigning the starting addresses of the remaining devices by adding each time 7 to the previous number. Make sure that you do not have any overlapping channels in order to control each Dataflower correctly. If two or more devices are addressed similarly, they will work similarly.
  • Page 21: Operation

    Control Modes The Dataflower can be operated with a DMX controller, and as a stand-alone device or in a master/slave setup without a DMX controller.
  • Page 22: Control Panel

    Dataflower Control Panel A) 4-digit LED display ENTER button C) DOWN button D) UP button MENU button Fig. 12 ● Use the MENU button to exit the current submenu, to return to the main menu and to scroll through the main menu.
  • Page 23: Menu Overview

    Dataflower Menu Overview Product code: 43168...
  • Page 24: Main Menu Options

    Dataflower Main Menu Options The main menu has the following options: DMX address Display LEDs DMX channel mode Display settings Slave mode Manual control Master mode Temperature Show mode Fixture hours Sound-controlled mode Version Sensitivity settings DMX fail Offset mode Press the UP/DOWN buttons or the MENU button to navigate through the main menu.
  • Page 25: Slave Mode

    Dataflower Slave Mode In this menu you can set the device as a slave device in master/slave control mode. 01) Press the UP/DOWN buttons to select one of the following 2 options: The device will operate as a slave device in...
  • Page 26: Sound Mode

    Dataflower Sound Mode In this menu you can activate the sound-controlled operation mode. 01) Press the UP/DOWN buttons to select one of the following 2 options: Sound-controlled operation mode is activated. The device will run the selected built-in program reacting to the beat of the music...
  • Page 27: Display Settings

    Dataflower The LED display will turn off after 15 seconds of Off: inactivity 02) Press the ENTER button to confirm the selection. Display Settings In this menu you can select the orientation of the display. 01) Press the UP/DOWN buttons to select one of the following 2 options:...
  • Page 28: Temperature

    Dataflower Temperature In this menu you can view the temperature of the LEDs. Fixture Hours In this menu you can view the total hours of operation of the LEDs and of the device. Version In this menu you can view the firmware version of the device.
  • Page 29: Dmx Channels

    Dataflower DMX Channels 2 Channels 2 CH Function Value Setting 000–012 Output blackout 013–039 Show 0 (all built-in programs) 040–066 Show 1 067–093 Show 2 094–120 Show 3 Show 121–147 Show 4 148–174 Show 5 175–201 Show 6 202–228 Show 7 229–255...
  • Page 30 Dataflower 5 CH 7 CH Function Value Setting 000–017 Open 018–027 Gobo 1 028–037 Gobo 2 038–047 Gobo 3 048–057 Gobo 4 058–067 Gobo 5 068–077 Gobo 6 Static Gobo Wheel 078–087 Gobo 7 088–097 Gobo 8 098–107 Gobo 9 108–117...
  • Page 31: Gobo Wheel And Color Wheel

    Dataflower Gobo Wheel and Color Wheel Static gobo wheel Color wheel Fig. 13 Product code: 43168...
  • Page 32: Troubleshooting

    Dataflower Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
  • Page 33: Maintenance

    Dataflower Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. WARNING Risk of burns due to hot surface Allow the device to cool down for at least 15 minutes before servicing or cleaning.
  • Page 34: Basic Cleaning Instructions

    Dataflower Basic Cleaning Instructions The external lens of the device must be cleaned periodically in order to optimize the light output. The cleaning schedule depends on the conditions at the site where the device is installed. When smoke or fog machines are used at the site, the device will need more frequent cleaning. On the other hand, if the device is installed in well-ventilated area, it will need less frequent cleaning.
  • Page 35: Deinstallation, Transportation And Storage

    Dataflower Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.
  • Page 36 ©2020 Showtec...