6. If the DIMM problem persists and there are no other DIMMs with the same indication, replace the
DIMM.
7. If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same
indication, confirm that the eXFlash DIMM is under warranty before replacement.
Related links
– Server features and specifications
– Removing a compute book
– Replacing a compute book
– Removing the compute book cover
– Replacing the compute book cover
– Removing a memory module
– Replacing a memory module
– eXFlash DIMMs
• 806f0a0c-2b82ffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
IMM has detected an Over Temperature Condition for Memory on Compute Book 2.
May also be shown as 806f0a0c2b82ffff or 0x806f0a0c2b82ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
Complete the following steps until problem is solved:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Check IBM Support site for Service Bulletins/RETAIN tips related to an Over Temperature
Condition.
5. If the problem persists and there are no other DIMMs with the same indication, replace the
DIMM.
Related links
– Server features and specifications
– Removing a compute book
– Replacing a compute book
– Removing the compute book cover
– Replacing the compute book cover
– Removing a memory module
1308
System x3850 X6 and x3950 X6 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents