Oracle Talari E1000 | Hardware Guide
Installing the Oracle Talari Appliance

Unpacking and Inspection

Remove E1000 appliance and accessories from box.
Remove E1000 from plastic wrapping.
Inspect appliance for signs of damage.
Remove foam insert wedged between faceplate and inner front of
appliance
by using thumbscrews on front of appliance to loosen faceplate. (Faceplate is
hinged and will swing down. See E1000 Front Panel section for location of
thumbscrews.)
Remove warning stickers from top of appliance faceplate and power receptacle.
Re-secure faceplate using thumbscrews.
Confirm appliance has expected hardware option. (See E1000 Back Panel
section to identify.)
Ensure all accessories are included.

Rack Mounting

The E1000 ships with hardware for a 4-Post Rack mount, or a 2-Post Rack mount. The
instructions below will provide the most efficient rack mounting of the device based
upon selected rack type.

Safety Recommendations

Prior to installing the device in a rack, adhere to the following rack
installation guidelines:
Ensure that there is adequate airflow in the rack. Restricted airflow can damage
the equipment.
Leave at least 1U of vertical space between each device installed in the rack.
The rack width and depth should allow for proper serviceability and cable
management.
Ensure the rack is properly secured to the floor or ceiling.
Ensure the rack is properly grounded.
Ensure the installer is properly grounded and wearing appropriate
safety equipment.
Always load the rack from the bottom up.
Load the heaviest devices in the rack first.
Make sure the rack is level and stable before pulling a device out of the rack.
Do not move racks by yourself; at least two people are recommended to move a
rack.
Cables should be easily identifiable.
1 4