Sharp JW Series Connection Manual

Computer link sio driver

Advertisement

JW Series Computer Link
SIO Driver
1
System Configuration....................................................................................................... 3
2
Selection Of External Device ............................................................................................ 8
3
Example Of Communication Setting ................................................................................. 9
4
Setup Items .................................................................................................................... 45
5
Cable Diagram ............................................................................................................... 50
6
Supported Device........................................................................................................... 79
7
Device Code And Address Code.................................................................................... 83
8
Error Messages.............................................................................................................. 87
Sharp Manufacturing Systems Corporation
1

Advertisement

Table of Contents
loading

Summary of Contents for Sharp JW Series

  • Page 1 Sharp Manufacturing Systems Corporation JW Series Computer Link SIO Driver System Configuration....................... 3 Selection of External Device .................... 8 Example of Communication Setting ................. 9 Setup Items ........................45 Cable Diagram ....................... 50 Supported Device......................79 Device Code and Address Code..................83...
  • Page 2 JW Series Computer Link SIO Driver Introduction This manual describes how to connect the Display and the External Device. In this manual, the connection procedure will be described by following the below sections: System Configuration "1 System Configuration" (page 3)
  • Page 3 JW Series Computer Link SIO Driver System Configuration The system configuration in the case when the External Device of Sharp Manufacturing Systems Corporation and the Display are connected is shown. Setting Cable Series Link I/F SIO Type Example Diagram Setting...
  • Page 4 JW Series Computer Link SIO Driver Setting Cable Series Link I/F SIO Type Example Diagram Setting Cable RS422/485 Example 8 Diagram 1 (4wire) (page 23) (page 50) JW-50CUH JW-10CM Setting Cable RS422/485 Example 9 Diagram 2 (2wire) (page 25) (page 54)
  • Page 5 JW Series Computer Link SIO Driver Setting Cable Series Link I/F SIO Type Example Diagram Setting Cable RS232C Example 13 Diagram 9 (page 33) (page 78) PG/COMM1 on the CPU unit Setting Cable RS422/485 Example 14 Diagram 5 (4wire) (page 35)
  • Page 6 JW Series Computer Link SIO Driver COM Port of IPC When connecting IPC with External Device, the COM port which can be used changes with series and SIO type. Please refer to the manual of IPC for details. Usable port...
  • Page 7 JW Series Computer Link SIO Driver Dip switch setting: RS-422/485 (4 wire) Dip switch Setting Description Reserve (always OFF) SIO type: RS-422/485 Output mode of SD (TXD) data: Always output Terminal resistance (220Ω) insertion to SD (TXD): None Terminal resistance (220Ω) insertion to RD (RXD): None...
  • Page 8 Select the maker of the External Device to be connected. Select "Sharp MS Corporation". Select a model (series) of the External Device to be connected and connection method. Select "JW Series Computer Link SIO". Check the External Device which can be connected in "JW Series Computer Link SIO" in Driver system configuration.
  • Page 9 JW Series Computer Link SIO Driver Example of Communication Setting Examples of communication settings of the Display and the External Device, recommended by Digital Electronics Corp., are shown. Setting Example 1 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace.
  • Page 10 JW Series Computer Link SIO Driver Settings of External Device Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting the switch to enable the setting.
  • Page 11 JW Series Computer Link SIO Driver Setting Example 2 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 12 JW Series Computer Link SIO Driver Settings of External Device Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting the switch to enable the setting.
  • Page 13 JW Series Computer Link SIO Driver Setting Example 3 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 14 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 15 JW Series Computer Link SIO Driver Setting Example 4 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 16 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 17 JW Series Computer Link SIO Driver Setting Example 5 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 18 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 19 JW Series Computer Link SIO Driver Setting Example 6 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 20 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 21 JW Series Computer Link SIO Driver Setting Example 7 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 22 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 23 JW Series Computer Link SIO Driver Setting Example 8 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 24 JW Series Computer Link SIO Driver Settings of External Device Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting the switch to enable the setting.
  • Page 25 JW Series Computer Link SIO Driver Setting Example 9 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 26 JW Series Computer Link SIO Driver Settings of External Device Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting the switch to enable the setting.
  • Page 27 JW Series Computer Link SIO Driver 3.10 Setting Example 10 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 28 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 29 JW Series Computer Link SIO Driver 3.11 Setting Example 11 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 30 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 31 JW Series Computer Link SIO Driver 3.12 Setting Example 12 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 32 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 33 JW Series Computer Link SIO Driver 3.13 Setting Example 13 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 34 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 35 JW Series Computer Link SIO Driver 3.14 Setting Example 14 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 36 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 37 JW Series Computer Link SIO Driver 3.15 Setting Example 15 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 38 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 39 JW Series Computer Link SIO Driver 3.16 Setting Example 16 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 40 JW Series Computer Link SIO Driver Settings of External Device Set the bit of system memory in the External Device to ON or OFF. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting to enable the setting.
  • Page 41 JW Series Computer Link SIO Driver 3.17 Setting Example 17 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 42 JW Series Computer Link SIO Driver Settings of External Device Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting the switch to enable the setting.
  • Page 43 JW Series Computer Link SIO Driver 3.18 Setting Example 18 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings ] from [System setting window] in workspace. Device Setting To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific Settings] of [Device/PLC Settings].
  • Page 44 JW Series Computer Link SIO Driver Settings of External Device Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details. Restart the power of the External Device after setting the switch to enable the setting.
  • Page 45 JW Series Computer Link SIO Driver Setup Items Set communication settings of the Display with GP-Pro Ex or in off-line mode of the Display. The setting of each parameter must be identical to that of External Device. "3 Example of Communication Setting" (page 9)
  • Page 46 JW Series Computer Link SIO Driver Setup Items Setup Description In case of no response from the External Device, use an integer from 0 to 255 to enter how Retry many times the Display retransmits the command. Use an integer from "0 to 255" to enter standby time (ms) for the Display from receiving Wait To Send packets to transmitting next commands.
  • Page 47 JW Series Computer Link SIO Driver Settings in Off-Line Mode • Please refer to Maintenance/Troubleshooting for more information on how to enter off-line mode or about operation. Maintenance/Troubleshooting "2.2 Offline Mode" Communication Settings To display the setting screen, touch [Device/PLC Settings] from [Peripheral Equipment Settings] in the off-line mode.
  • Page 48 JW Series Computer Link SIO Driver Setup Items Setup Description Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the Timeout response from the External Device. In case of no response from the External Device, use an integer from 0 to 255 to enter how Retry many times the Display retransmits the command.
  • Page 49 JW Series Computer Link SIO Driver Option To display the setting screen, touch [Device/PLC Settings] from [Peripheral Equipment Settings]. Touch the External Device you want to set from the displayed list, and touch [Option]. Setup Items Setup Description Switches RI/VCC of the 9th pin.
  • Page 50 JW Series Computer Link SIO Driver Cable Diagram The cable diagram shown below may be different from the cable diagram recommended by Sharp Manufacturing Systems Corporation. Please be assured there is no operational problem in applying the cable diagram shown in this manual.
  • Page 51 JW Series Computer Link SIO Driver A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter (CA3-ADPTRM-01) by Pro-face and your own cable • 1:1 Connection External Device Shield Terminal block Terminal resistance Signal name Signal name Ω...
  • Page 52 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device D-Sub 9 pin (socket) Shield Terminal block Shield Terminal block Terminal resistance Signal name Signal name Signal name Ω (1/4W) Terminal resistance Ω (1/4W) Display Shield Shield...
  • Page 53 JW Series Computer Link SIO Driver D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable • 1:1 Connection D-Sub 9 pin (plug) External Device Terminal block Signal name Shield Termination resistance TERMRX Signal name 220 Ω (1/4W)
  • Page 54 JW Series Computer Link SIO Driver Cable Diagram 2 Display Cable Remarks (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 Your own cable Your own cable Online adapter by Pro-face...
  • Page 55 JW Series Computer Link SIO Driver A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter (CA3-ADPTRM-01) by Pro-face and your own cable • 1:1 Connection External Device Terminal block Terminal resistance Signal name Signal name Shield Ω...
  • Page 56 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device Terminal block D-Sub 9 pin (socket) Terminal block Termination resistance Signal name Signal name Signal name Shield 220 Ω (1/4W) Shield Display Shield Shield SW7: OFF SW7: ON Shell C.
  • Page 57 JW Series Computer Link SIO Driver D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable • 1:1 Connection D-Sub 9 pin (plug) External Device Signal name Terminal block Terminal resistance TERMRX Signal name Shield Ω (1/4W)
  • Page 58 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device Terminal block Terminal block Terminal resistance Signal name Signal name Signal name Shield Shield (1/4W) Display CA3-ADPCOM-01 CA3-ADPTRM-01 Shield Shield SW7: OFF SW7: ON Your own cable F.
  • Page 59 JW Series Computer Link SIO Driver Cable Diagram 3 Display Cable Remarks (Connection Port) GP (COM1) Cable length: Your own cable 15m or less Only the COM port which can communicate by RS-232C can be used. COM Port of IPC (page 6)
  • Page 60 JW Series Computer Link SIO Driver Cable Diagram 4 Display Cable Remarks (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 Your own cable Your own cable Online adapter by Pro-face...
  • Page 61 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device D-Sub 15 pin (plug) D-Sub 15 pin (plug) Terminal Shield Shield resistance Signal name Signal name Signal name Ω (1/4W) Display SD(+) SD(+) CA3-ADPCOM-01 SD(-) SD(-) RD(+)
  • Page 62 JW Series Computer Link SIO Driver C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM- 01) by Pro-face and your own cable • 1:1 Connection External Device D-Sub 15 pin (plug) Terminal Shield resistance Signal name Signal name Ω...
  • Page 63 JW Series Computer Link SIO Driver • 1:n Connection D-Sub 9 pin (plug) External Device External Device Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug) Terminal Shield Shield resistance TERMRX Signal name Signal name Ω (1/4W) Display CA4-ADPONL-01...
  • Page 64 JW Series Computer Link SIO Driver Cable Diagram 5 Display Cable Remarks (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 Your own cable Your own cable Online adapter by Pro-face...
  • Page 65 JW Series Computer Link SIO Driver A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter (CA3-ADPTRM-01) by Pro-face and your own cable • 1:1 Connection External Device D-Sub 15 pin (plug) Shield Signal name Signal name...
  • Page 66 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device D-Sub 15 pin (plug) D-Sub 15 pin (plug) D-Sub 9 pin (socket) Shield Shield Signal name Signal name Signal name SD(+) SD(+) SD(-) SD(-) Display RD(+) RD(+)
  • Page 67 JW Series Computer Link SIO Driver D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable • 1:1 Connection D-Sub 9 pin (plug) External Device Signal name D-Sub 15 pin (plug) Shield TERMRX Signal name Display CA4-ADPONL-01...
  • Page 68 JW Series Computer Link SIO Driver Cable Diagram 6 Display Cable Remarks (Connection Port) GP (COM1) Cable length: Your own cable 15m or less Only the COM port which can communicate by RS-232C can be used. COM Port of IPC (page 6)
  • Page 69 JW Series Computer Link SIO Driver Cable Diagram 7 Display Cable Remarks (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 Your own cable Your own cable Online adapter by Pro-face...
  • Page 70 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device D-Sub 15 pin (plug) D-Sub 15 pin (plug) Terminal Shield Shield resistance Signal name Signal name Signal name Ω (1/4W) Display TxD(+) TxD(+) CA3-ADPCOM-01 TxD(-) TxD(-) RxD(+)
  • Page 71 JW Series Computer Link SIO Driver C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM- 01) by Pro-face and your own cable • 1:1 Connection External Device D-Sub 15 pin (plug) Terminal Shield resistance Signal name Signal name Ω...
  • Page 72 JW Series Computer Link SIO Driver • 1:n Connection D-Sub 9 pin (plug) External Device External Device Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug) Terminal Shield Shield resistance TERMRX Signal name Signal name Ω (1/4W) TxD(+) TxD(+)
  • Page 73 JW Series Computer Link SIO Driver Cable Diagram 8 Display Cable Remarks (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 Your own cable Your own cable Online adapter by Pro-face...
  • Page 74 JW Series Computer Link SIO Driver A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter (CA3-ADPTRM-01) by Pro-face and your own cable • 1:1 Connection Signal name Shield External Device Terminal block Display Signal name...
  • Page 75 JW Series Computer Link SIO Driver • 1:n Connection D-Sub 9 pin (socket) Signal name Shield External Device External Device Terminal block Terminal block Shield Signal name Signal name Display Shield Shield Shell C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM- 01) by Pro-face and your own cable •...
  • Page 76 JW Series Computer Link SIO Driver D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable • 1:1 Connection D-Sub 9 pin (plug) Signal name TERMRX Shield External Device Display Terminal block CA4-ADPONL-01 Signal name Shield TERMTX...
  • Page 77 JW Series Computer Link SIO Driver • 1:n Connection External Device External Device Terminal block Terminal block Signal name Signal name Signal name Shield Shield Display CA3-ADPCOM-01 Shield Shield CA3-ADPTRM-01 Your own cable F. When your own cable is used •...
  • Page 78 JW Series Computer Link SIO Driver Cable Diagram 9 Display Cable Remarks (Connection Port) GP (COM1) Cable length: Your own cable 15m or less Only the COM port which can communicate by RS-232C can be used. COM Port of IPC (page 6)
  • Page 79 JW Series Computer Link SIO Driver Supported Device Range of supported device address is shown in the table below. Available type and range of device vary depending on CPU. Be sure to check them in each CPU manual before using.
  • Page 80 JW Series Computer Link SIO Driver Device Bit Address Word Address Remarks bits 1000000-1177776 2000000-2177776 ..6000000-6177776 7000000-7177776 F10000000-F10177776 F11000000-F11177776 File Register ..F1E000000-F1E177776 F1F000000-F1F177776 F20000000-F20177776 F21000000-F21177776 ..F2B000000-F2B177776 F2C000000-F2C177776 Values in parentheses are used for the word address of the relay and the timer counter (current value) (B) in the manual of the External Device.
  • Page 81 JW Series Computer Link SIO Driver JW-300 Series This address can be specified as system data area. Device Bit Address Word Address Remarks bits A00000-A54376 Relay 00000.0-54377.7 (]00000-]54376) Timer (Contact) T00000-T17777 Counter (Contact) C00000-C17777 B00000-B37776 Timer Counter (current value) TC00000-TC17777...
  • Page 82 JW Series Computer Link SIO Driver • Please refer to the GP-Pro EX Reference Manual for system data area. GP-Pro EXReference Manual "Appendix 1.4 LS Area (only for direct access method)" • Please refer to the precautions on manual notation for icons in the table.
  • Page 83 JW Series Computer Link SIO Driver Device Code and Address Code Use device code and address code when you select "Device Type & Address" for the address type in data displays. JW-10/20H/30H/50H/70H/100H Series Device Code Device Device Name Address Code...
  • Page 84 JW Series Computer Link SIO Driver Device Code Device Device Name Address Code (HEX) 0012 Value of word address divided by 2 0013 Value of word address divided by 2 ....0017 Value of word address divided by 2...
  • Page 85 JW Series Computer Link SIO Driver JW-300 Series Device Code Device Device Name Address Code (HEX) Relay 0080 Value of word address divided by 2 0061 Value of word address divided by 2 Timer/Counter (Current Value) 0060 Word Address 0000...
  • Page 86 JW Series Computer Link SIO Driver Device Code Device Device Name Address Code (HEX) 0040 Value of word address divided by 2 0041 Value of word address divided by 2 0042 Value of word address divided by 2 0043 Value of word address divided by 2...
  • Page 87 JW Series Computer Link SIO Driver Error Messages Error messages are displayed on the screen of the Display as follows: "No. : Device Name: Error Message(Error Occurrence Area)". Each description is shown below. Item Requirements Error No. Name of the External Device where error occurs. Device name is a title of the External Device Name Device set with GP-Pro EX.((Initial value[PLC1])
  • Page 88 JW Series Computer Link SIO Driver GP-Pro EX Device/PLC Connection Manual...

Table of Contents