Settings of External Device
Use the rotary switch on Link I/F for setting. Please refer to the manual of the External Device for more details.
Restart the power of the External Device after setting the switch to enable the setting.
Function Setting Switch
Rotary Switch
SW0
Station Setting Switch
Rotary Switch
SW2 (x10)
SW1 (x1)
• Set the station No. between 01 and 37 (o) with SW2 and SW1.
Operation ModeSetting Switch
DIP Switch
SW3-1
SW3-2
SW3-3
SW3-4
Transfer Speed Setting Switch
Rotary Switch
SW4
Termination Resistance Switch
DIP Switch
SW7
Unit No. Switch
Rotary Switch
SW8
GP-Pro EX Device/PLC Connection Manual
Setting
Value
4
SIO Type: Computer link
Setting
Value
0
Station No. setting: Set the upper station number.
1
Station No. setting: Set the lower station number.
Setting
Value
OFF
Reserved
ON
Number of communication wire: 4 wire
OFF
Reserved
ON
Parity: Even
Setting
Value
0
Transmission speed: 19200bps
Setting
Value
Insert the termination resistance: Set it to ON to insert the termination resistance.
ON
Set only the External Device which terminates the connection to ON.
Setting
Value
0
Set the data memory address for sub station 01 to 04.
JW Series Computer Link SIO Driver
Setup Description
Setup Description
Setup Description
Setup Description
Setup Description
Setup Description
42