Page 3
Set enable / disable OCR func on by SIM LAN Cable LAN Port RS232C Cable Scan Accessory Kit IP address IP address Two IP addresses are needed for MFP and needed for MFP and Scan Accessory Kit. MX-AP14 PRODUCT OUTLINE 1 – 1...
Page 4
Power consumption 60W or less at maximum Dimension 523mm(W) x 52mm(D) x 229mm(H) 20 19/32” (W) x 2-3/64” (D) x 9-1/64 (H) Weigh Approx. 2.22kg 4.90 lbs ・OCR application Pre-installation application ・Maintenance tool ・Anti virus software MX-AP14 SPECIFICATIONS 2 – 1...
Page 5
Remove the shield plate. B. Necessary parts For MX-M654N/M754N Installing kit (DKIT-0453FCZZ) Remove the connector, screws. Remove the MFP control Name Quantity PWB. Fixing plate right Fixing plate left Damper Screw (M4x16S) Step screw MX-AP14 UNPACKING AND INSTALLATION 3 – 1...
Page 6
Attach the locking saddle (Packed item No.6) to the Main unit. Hang a main unit (Packed item No.1) to the screw which did procedure 4) and fix it with a screw (Packed item No.9) for installation. Remove the back cover from the desk. MX-AP14 UNPACKING AND INSTALLATION 3 – 2...
Page 7
Connect with Power cord (Packed item No.2), and connect Power cord fixing (Packed item No.3) to the Main unit. Put the LAN cable to the locking saddle. Put power cord fixing to the power cord. MX-AP14 UNPACKING AND INSTALLATION 3 – 3...
Page 8
MFP. In case of turning power off of Main unit, push one time to [BOOT/SHUTDOWN] button (within 1 sec) Main unit has stopped, power indicator lamp is lights off. MX-AP14 UNPACKING AND INSTALLATION 3 – 4...
Page 9
Connect the cable to the MFP PWB. Ring form made by procedure 5) should be shown below. Remove the screws and pull out the MFP PWB unit. Put MFP PWB back to the MFP and all the covers removed. MX-AP14 UNPACKING AND INSTALLATION 3 – 5...
Page 10
4) and fix it with a screw (Packed item No.9) for installation. Make hole for screw installation through the hollow of the cover surface with screwdrivers. Fix the screws which did procedure 4). Attach the earth plate to the desk rear cover. MX-AP14 UNPACKING AND INSTALLATION 3 – 6...
Page 11
D. Turning power on NOTE: Do not connect RS-232C cable to this port. Plug in and turning power on of the Main unit . (NOTE) Do not connect Put the RS-232C cable to the locking saddle then locked. MX-AP14 UNPACKING AND INSTALLATION 3 – 7...
Page 12
Cut the line of the cover from back side. Turning power off of the Main unit. Remove the screws and pull out the MFP PWB unit. Plug off of the Main unit. MX-AP14 UNPACKING AND INSTALLATION 3 – 8...
Page 13
Set the upper damper to the top hole and fit the lower damper into the bottom hole of the fixing plate. (Do the same for both sides) Put MFP PWB back to the MFP and all the covers removed. MX-AP14 UNPACKING AND INSTALLATION 3 – 9...
Page 14
NOTE: Do not connect RS-232C cable to this port. (NOTE) Do not connect Fix the main unit with the step screws. (Packed item No.5 of installing kit and step5) Put the RS-232C cable to the locking saddle then locked. MX-AP14 UNPACKING AND INSTALLATION 3 – 10...
Page 15
D. Turning power on Plug in and turning power on of the Main unit . Turning power off of the Main unit. Plug off of the Main unit. MX-AP14 UNPACKING AND INSTALLATION 3 – 11...
Page 16
Accessory Kit. Touch Edit Home on the operation panel. Touch Exit Home Edit Mode. Completed registration of icon on the display. Enter your administrator password and touch OK. Select the registration position of icon. MX-AP14 UNPACKING AND INSTALLATION 3 – 12...
Page 17
Use this button to start or shut down this product B. Internal structure Name Name Control PWB Controls image data DC power PWB Generates the DC voltage Store image data and used as a work memory MX-AP14 EXTERNAL VIEW AND INTERNAL STRUCTURES 4 – 1...
Page 18
Function (Purpose) Display the system configuration (options and internal hardware). Section Operation/Procedure The system configuration is displayed. (The model names of the installed devices and options are dis- played.) Device Model name Content CONNECT Scan accessory kit MX-AP14 SIMULATION 5 – 1...
Page 19
Some other warning mes- ment List trouble n-To block code sages must be cleared by a simulation. print Send print Special function (00) error MX-AP14 SELF DIAG MESSAGE AND TROUBLE CODE 6 – 1...
Page 20
RS-232C PWB and MFP PWB (Disconnection of RS-232C cable etc) *Disconnection/breakage of LAN cable between Scan Accessory Kit and MFP. *Improper IP address setting for Scan Accessory Kit. *During Scan Accessory Kit firmware update. MX-AP14 SELF DIAG MESSAGE AND TROUBLE CODE 6 – 2...
Page 21
Content of communication interruption code column of result NG90 XXXX Failed to convert the data for Image Send after reservation by Document Filing Output operation. Failed to convert the data for Image Send MX-AP14 SELF DIAG MESSAGE AND TROUBLE CODE 6 – 3...
Page 22
Touch [Scan Accessory Kit Settings] key on home screen of the operation panel. Display file name with extension HDI in the USB memory root folder. Select and touch [Start] key. Enter your password in the admin login screen. MX-AP14 FIRMWARE UPDATE 7 – 1...
Page 23
Scan Accessory Kit. NOTE: Do not insert a USB memory until the firmware update is completed. Display [Firmware Update. Now Processing...] (Do not close current screen or turning the power off during this process). MX-AP14 FIRMWARE UPDATE 7 – 2...
Page 24
Turning power off of the Main unit. Connect USB memory to Scan Accessory Kit and touch [Select USB memory] key of Export of System Settings. Disconnect the cable and remove Scan Accessory Kit from the MFP. MX-AP14 VARIOUS STORAGE DATA HANDLING 8 – 1...
Page 25
Scan Accessory Kit. 15) Touch [Select USB Memory] key of Import of System Settings that the destination of export file done by procedure 5). 16) Set network setting. MX-AP14 VARIOUS STORAGE DATA HANDLING 8 – 2...
Page 28
Plug in and turning the power on of the Main unit. Enter your password in the admin login screen. Push one time to [BOOT/SHUTDOWN] button to boot up the Touch [System Settings] key from top menu. Main unit. Touch [Start] key of Restore Factory Defaults. MX-AP14 OTHERS 10 – 1...
Page 30
CAUTION FOR BATTERY REPLACEMENT (Danish) ADVARSEL ! Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandoren. (English) Caution ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Page 31
NEC, PC-9821, and PC98-NX are registered trademarks or trademarks of NEC Corporation. Sharpdesk is a trademark of Sharp Corporation. Sharp OSA is a trademark of Sharp Corporation. RealVNC is a trademark of RealVNC Limited. All other trademarks and copyrights are the property of their respective owners.
Need help?
Do you have a question about the MX-AP14 and is the answer not in the manual?
Questions and answers