How To Implement The General Inspection - Owon TAO 3000 Series Quick Manual

Dual-channel tablet oscilloscopes
Hide thumbs Also See for TAO 3000 Series:
Table of Contents

Advertisement

"RP" the Phase A->B , "FP" the Phase A->B , "+PC" the +Pulse count, "-PC"
the - Pulse count, "+E" the Rise edge count, "-E" the Fall edge count, "AR" the
Area, "CA" the Cycle area.
23. The readings show the record length.
24. The readings show current sample rate.
25. The readings indicate the corresponding Voltage Division of the channels.
"BW" indicates bandwidth limit.
The icon shows the coupling mode of the channel.
"—" indicates direct current coupling
"~" indicates AC coupling
"
" indicates GND coupling
26. The reading shows the setting of main time base.
27. It is cursor measure window, showing the absolute values and the readings of the
cursors.
28. The blue pointer indicates the grounding datum point (zero point position) of the
waveform of the CH2 channel.
29. The yellow pointer indicates the grounding datum point (zero point position) of
the waveform of the CH1 channel.

How to Implement the General Inspection

After you get a new oscilloscope, it is recommended that you should make a check on
the instrument according to the following steps:
1. Check whether there is any damage caused by transportation.
If it is found that the packaging carton or the foamed plastic protection cushion has
suffered serious damage, do not throw it away first till the complete device and its
accessories succeed in the electrical and mechanical property tests.
2. Check the Accessories
The supplied accessories have been already described in the "Appendix A: Enclosure"
of this Manual. You can check whether there is any loss of accessories with reference
to this description. If it is found that there is any accessory lost or damaged, please get
in touch with the distributor of OWON responsible for this service or the OWON's
local offices.
3. Check the Complete Instrument
If it is found that there is damage to the appearance of the instrument, or the
instrument can not work normally, or fails in the performance test, please get in touch
with the OWON's distributor responsible for this business or the OWON's local
offices. If there is damage to the instrument caused by the transportation, please keep
the package. With the transportation department or the OWON's distributor
responsible for this business informed about it, a repairing or replacement of the
3.Quick Start
8

Advertisement

Table of Contents
loading

Table of Contents