Remote functions
WFM 1125 Option 0A/0B/0C/0D Service Manual
Initial Setups.
H TSG1001:
FORMAT:
. . . . . . . . . . . . . . . .
SWEEP:
. . . . . . . . . . . . . . . . .
H
The Waveform Monitor:
INPUT:
. . . . . . . . . . . . . . . . . .
1. Press the REF EXT button on the waveform monitor front panel to set the
reference mode to external.
2. Confirm that the field rate readout at the right upper corner on the screen
indicates 60.00 Hz.
3. Disconnect the BNC cable from the ANALOG OUT Y output on the
waveform monitor rear panel, and then connect it to the BLACK output on
the NTSC TV generator rear panel.
4. Press and hold the INTEN/MENU button on the waveform monitor front
panel to display the Configure menu, and then select EXT REFERENCE :
NTSC from the menu.
5. Confirm that the field rate readout at the right upper corner on the screen
indicates 59.94 Hz and the waveform is not locked.
This test confirms that the remote operation is functioning correctly.
The following equipment is required.
Equipment Required
Connections. Refer to Figure 4–6 for connections.
Using the cables supplied with the PSC1125, connect between the G/Y on the
TSG1001 and Y on the PSC1125, and between the B/Pb on the TSG1001 and
P
/P
on the PSC1125.
B
R
Using the 75 W BNC cable, connect the OUT1 connector on the PSC1125 rear
panel to the CH A connector on the waveform monitor rear panel.
SMPTE 274M 60Hz (for Option 0A)
SMPTE 296M (for Option 0B)
100 %
CH A
HDTV signal generator (TSG1001 and PSC1125)
Two parallel signal cables
75 W BNC cable
Ground closer with 15 pin, D type connector
Performance Verification
4-19