Grundfos CIM 500 Installation And Operating Instructions Manual

Grundfos CIM 500 Installation And Operating Instructions Manual

Ethernet module
Hide thumbs Also See for CIM 500:

Advertisement

Quick Links

GRUNDFOS INSTRUCTIONS
CIM 500 Ethernet module
Installation and operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CIM 500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grundfos CIM 500

  • Page 1 GRUNDFOS INSTRUCTIONS CIM 500 Ethernet module Installation and operating instructions...
  • Page 2: Table Of Contents

    English (GB) Installation and operating instructions 1. General information Original installation and operating instructions These installation and operating instructions describe the Grundfos CIM 500 Ethernet module. 1.1 Hazard statements Sections 1-3 provide the information necessary to be The symbols and hazard statements below may able to install and start up the product in a safe way.
  • Page 3: Applications

    2. Applications Media Access Control. Unique address for a piece of hardware. The CIM 500 Ethernet module enables data transmission between an Industrial Ethernet network Medium Dependent Interface. and a Grundfos product. Packet InterNet Groper. A software The module supports various Industrial Ethernet...
  • Page 4: Cim 500 Ethernet Module

    Consider contacting an IT Infrastructure Specialist to connector 1 establish such a solution. Data activity LED for For CIM 500 in mode 4, GRM IP (Grundfos Remote DATA2 RJ45 connector 2 Management) the firewall must accept connections initialised by the Grundfos product to the Internet...
  • Page 5: Connecting The Ethernet Cable

    Ethernet ports. Each Ethernet port has its own MAC address and CIM 500 has a built-in switch which means that the cable can run another 100 metres whenever passing a CIM 500 module.
  • Page 6: Selection Of Industrial Ethernet Protocol

    IP settings for EtherNet/IP a DHCP server. Note that BACnet IP BACnet IP and the webserver GRM IP for Grundfos Remote share the same IP address. Management, requires a contract with Grundfos. It can be given a fixed value via the webserver, or it can use...
  • Page 7: Connection To The Webserver

    PC parallel to the router (RJ45 port 1) built-in webserver. To establish a connection from at CIM 500 RJ45 port 2. Look at the router a PC to CIM 500, proceed as follows: webserver which address the router assigns to the 1.
  • Page 8: Status Leds

    Wink function. LED flashes BACnet Flashing green 10 times when activated from the Resetting to factory settings. PROFINET master. Flashing red After 20 seconds CIM 500 and green Permanently The module is in cyclic data restarts. green exchange mode. LED1, EtherNet/IP...
  • Page 9: Data Activity And Link Leds

    GRM. LINK1 and LINK2 These green LEDs show whether the Ethernet cable Resetting to factory settings. Flashing red is properly connected to the RJ45 connector in After 20 seconds CIM 500 and green question. restarts. LED2, all fieldbuses Status...
  • Page 10: Fault Finding

    You can detect faults in a module by observing the status of the two status LEDs. See the tables below. CIM 500 fitted in a Grundfos product or CIM 500 fitted in a CIU 500 Ensure that SW1 is in position "0" to select PROFINET.
  • Page 11: Modbus Tcp Or Bacnet Ip

    You can detect faults in a module by observing the status of the two status LEDs. See the tables below. CIM 500 fitted in a Grundfos product or CIM 500 fitted in a CIU 500 Ensure that SW1 is in position "1" if Modbus should be selected or in position "2"...
  • Page 12: Ethernet/Ip

    You can detect faults in a module by observing the status of the two status LEDs. See the tables below. CIM 500 fitted in a Grundfos product or CIM 500 fitted in a CIU 500 Ensure that SW1 is in position "3".
  • Page 13: Grm Ip

    You can detect faults in a module by observing the status of the two status LEDs. See the tables below. CIM 500 fitted in a Grundfos product or CIM 500 fitted in a CIU 500* Ensure that SW1 is in position "4" to select GRM IP.
  • Page 14: Technical Data

    350 mA max. -25 to +70 °C Storage temperature -13 to +158 °F Requires a contract with Grundfos. 7.1 PROFINET technical specifications • PROFINET device according to Conformance Class B • Media Redundancy Protocol (MRP) Client Functionality PROFINET RT • System redundancy S2 •...
  • Page 15: Modbus Tcp Technical Specifications

    Certificate To optimise data security when using Modbus TCP via a cellular router, Grundfos strongly recommends that the cellular data connection is based on a private APN with static IP and with no access to public Internet.
  • Page 16: Ethernet/Ip Technical Specifications

    • Quality of Service (QoS) • IPv4 Address Conflict Detection (ACD) Communication watchdog with fixed 5 seconds Watchdog time-out. It can be enabled via the CIM 500 web page. Certificate Plugfest December 2018, Conformance July 2019. 8. Disposal This product or parts of it must be disposed of in an environmentally sound way: 1.
  • Page 17 Appendix Webserver configuration The built-in webserver offers easy monitoring of the CIM 500 module and makes it possible to configure the selected Industrial Ethernet protocol. Using the webserver, you can also update the firmware of the CIM 500 module and store or restore settings, among other functions.
  • Page 18 • at least one upper case letter • at least one numeric or special character. When logging you have four attempts before a back-off algorithm starts an exponentially increasing time delay between each attempt. Power cycling CIM 500 resets the back-off algorithm.
  • Page 19 This field is read only. The IP address is assigned from the PLC. PROFINET IO is not IP Address allowed to share the IP address with a CIM 500 webserver. Subnet Mask This field is read only. The subnet mask is assigned from the PLC.
  • Page 20 Configuration of the static IP address if a DHCP server is not used. Modbus TCP is not IP Address allowed to share the IP address with a CIM 500 webserver. Subnet Mask Configuration of the subnet mask if a DHCP server is not used.
  • Page 21 BACnet IP. Select Device Instance. The default number is 22700. The Device Instance must be unique in Device Instance the BACnet network. For Grundfos, the number is 227 and it is fixed. The last three digits can be changed. Device Name You can name the device.
  • Page 22 Configuration of the subnet mask if a DHCP server is not used. Gateway Configuration of the gateway address if a DHCP server is not used. The CIM 500 module can be configured to automatically obtain its EtherNet/IP network Use DHCP settings from a DHCP server, if available on the network.
  • Page 23 Real Time Ethernet Protocol Configuration, GRM IP Object Description GRMIP Port A change is only needed in case Grundfos requires it. Number The default URL link to the GRM Server is active but hidden. A change is only needed in case Grundfos requires it.
  • Page 24 Network Settings This web page is used to configure the network settings of the webserver and of the GENIpro TCP protocol. The network settings here are also used for BACnet IP. Additional configuration of BACnet IP is done in the Real Time Ethernet Protocol menu.
  • Page 25 GENIpro TCP port settings This web page is only present when the Modbus TCP protocol has been selected, SW1 is in position 1. The module can connect to a Grundfos PC tool and communicate with the product via the GENIpro TCP protocol.
  • Page 26 User Management A login is required for any change of the CIM 500 settings, and this web page is used to configure the username and password. See Login. It is only possible to configure one user. Fig. 10 User management...
  • Page 27 Update You can update the firmware by means of the built-in webserver. The binary file is supplied by Grundfos. To make installation and configuration easier, you can upload the configuration to a PC for backup or distribution to multiple modules.
  • Page 28 Appendix 中国 RoHS...
  • Page 29 We, Grundfos, declare under our sole responsibility that the product Wir, Grundfos, erklären in alleiniger Verantwortung, dass das Produkt CIM 500, to which the declaration below relates, is in conformity with CIM 500, auf das sich diese Erklärung bezieht, mit den folgenden...
  • Page 30 Руководство по эксплуатации ЕАС...
  • Page 31 CIM 500 CIM 500 CIM 500 CIM 500 CIM 500 « »: « » « ».
  • Page 32 CIM 500 . TR TS 004/2011« voltage »; TR TS 020/2011 « »: http://net.grundfos.com/qr/i/99800478 10000274311 0120 ECM: 1279071...
  • Page 34 Argentina China Hong Kong Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Pumps (Hong Kong) Ltd. Ruta Panamericana km. 37.500 Centro 10F The Hub, No. 33 Suhong Road Unit 1, Ground floor Industrial Garin Minhang District Siu Wai Industrial Centre 1619 Garín Pcia.
  • Page 35 Malaysia Serbia Turkey GRUNDFOS Pumps Sdn. Bhd. Grundfos Srbija d.o.o. GRUNDFOS POMPA San. ve Tic. Ltd. 7 Jalan Peguam U1/25 Omladinskih brigada 90b Sti. Glenmarie Industrial Park 11070 Novi Beograd Gebze Organize Sanayi Bölgesi 40150 Shah Alam Phone: +381 11 2258 740...
  • Page 36 98407037 0320 ECM: 1283002 www.grundfos.com...

Table of Contents