B.2. Modbus Register Map
Coil-type variables (0xxxx, 0 based)
Modbus Address
Decimal
Hex.
00000
0000
:
:
00039
0027
00100
0064
:
:
00227
00E3
System variables (3xxxx, 0 based)
Modbus Address
Decimal
Hex.
30000
0000
:
:
30003
0003
30004
0004
:
:
30007
0007
30008
0008
:
:
30011
000B
30012
000C
30013
000D
30014
000E
30015
000F
30016
0010
iKAN Series Display User Manual
Length
40
Coil-type variables
Enables or disables the display of
128
common messages 0 to 127.
Length
The IP address for the iKAN series
4
device
The Mask address for the iKAN
4
series device
The Gateway address for the iKAN
4
series device
1
Year
1
Month
1
Day
Abbreviated day of the week: SUN,
1
MON, TUE, WED, THU, FRI, SAT
Day of the week: Sunday, Monday,
1
Tuesday, Wednesday, Thursday,
Friday, Saturday
Description
Description
v 1.0.1
Value
Attribute
Range
-
R/W
0: Disabled
R/W
1: Enabled
Value
Attribute
Range
0 to 255
R
0 to 255
R
0 to 255
R
0 to 9999
R
1 to 12
R
1 to 31
R
0 to 6
R
0 to 6
R