Set Up Mega 360 On The Network; Solix Series Networking - Humminbird MEGA 360 IMAGING Operation Manual

Hide thumbs Also See for MEGA 360 IMAGING:
Table of Contents

Advertisement

Set Up MEGA 360 on the Network

Use the instructions in this section if you have more than one Humminbird control head connected to the network. Configuring the
network synchronizes the control head settings.
NOTE: If you have selected the MEGA 360 Imaging transducer on the network during the installation, the other settings in this section
are optional. The depth source, temperature source, and alarms will be selected automatically based on the other connected
equipment. Use this section to confirm installation settings or to change the sources to your preference. The settings will be saved
after you power off the control head.
Before you start, make sure all of your control heads and sources (GPS, transducers, temp/speed accessories, etc.) for your fishing
system have been installed. See the equipment installation guides for details. You may need to purchase an Ethernet switch,
Ethernet connection cables, or y-cables, depending on your setup.
When the Humminbird network is installed, each control head automatically selects a primary source (transducer, temperature,
and GPS). The control head selects the equipment connected to it as its primary source, but you can choose any compatible source
on the network. Make sure to review the MEGA 360 Installation Guide to ensure MEGA 360 Imaging is set up as the sonar source.
NOTE: The MEGA 360 Imaging transducer can be connected in conjunction with HW, HW/MEGA DI+, HW/MEGA DI+/MEGA SI+
transducers, as well as built-in MEGA DI+ and built-in MEGA SI+ from a Minn Kota trolling motor.
NOTE: The MEGA 360 Imaging transducer can be connected to a SOLIX unit and shared with other SOLIX units over the Ethernet, or
the MEGA 360 can be connected to a HELIX G3N unit and shared with other HELIX G3N and G2N units over the Ethernet.

SOLIX Series Networking

When you select the MEGA 360 Imaging transducer on the network, the related views and menus will be added to the control head.
Open the Sonar Source Menu
1. Press the HOME key.
2. Select Settings.
3. Select CHIRP Sonar.
4. Select Sonar Source.
Select Sonar Sources
Use the instructions in this section to assign sonar sources to each control head. The sonar sources can be shared between control
heads or you can use different sonar sources on each control head.
1. From the Sonar Source menu, select the tab for the sonar source you want to assign.
The MEGA 360 Imaging transducer will be displayed on the Side Imaging and 360 Imaging tabs.
2. Select the transducer connection location. The connection locations are displayed as follows:
Selected Control Head (Local): the control head you are actively using
Remote Control Head: additional control heads connected to the network
Black Box Sonar
3. Repeat steps 1 and 2 for each tab. You can select one sonar source on each tab.
When you turn on/off pinging or change the transducer settings, all control heads sharing the transducer are affected.
17
Set Up the Network

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents