Configuration Number Matrix; Key Points - Graco Python A25115 Instructions - Parts Manual

Chemical injection pump
Table of Contents

Advertisement

Configuration Number Matrix

Configuration Number Matrix
Check the identification plate (ID) for the 12-digit Configuration Number of your pump. Use the following matrix to
define the components of your pump.
NOTE: Not all combinations are possible.
Sample Configuration Number: PCI-125-19S-XA-A
PCI
125
Pneumatic
Air Motor Size
Chemical
Injection
Air Motor Size
Plunger Size
125 1-1/4 inch 13 1/8" Diameter S
175 1-3/4 inch 19 3/16" Diameter H High Pressure
200 2 inch
25 1/4" Diameter
38 3/8" Diameter
50 1/2" Diameter
63 5/8" Diameter
75 3/4" Diameter

Key Points

Standard pressure pumps feature 1/4 in. NPT(F)
inlet and outlet connections.
High pressure pumps feature 1/4 in. NPT(F) inlet
and HiP HF4 outlet connections.
B32240 can be used to convert HF4 outlet connec-
tion to 1/4 in. NPT(F) for applications 10,000 psi and
under.
4
19
S
Plunger Size Pressure Range Plunger Material
Pressure Range
Standard Pressure
(1/4", 3/8", 1/2", 5/8",
3/4" plungers)
(1/8" & 3/16" plung-
ers)
X
Plunger Material
C Ceramic Coated
A
17-4 PH Stainless
X
Chromex Coated
B
17-4 PH Stainless
C HNBR
D FFKM
A
A
Seal Material Qualifier
Seal
Material
Qualifier
FKM
A
ATEX
FKMETP
3A4386E

Advertisement

Table of Contents
loading